Difference between revisions of "Site considerations"

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
Line 15: Line 15:
 
!Wellhead protection area<ref>| Drinking Water Source Protection wellhead protection area time of travel</ref>
 
!Wellhead protection area<ref>| Drinking Water Source Protection wellhead protection area time of travel</ref>
 
|-
 
|-
|'''[[Rain barrels|Rain Barrel]]'''
+
|'''[[Rain barrels|Rain Barrels]]'''
 
|Not applicable
 
|Not applicable
 
||5 to 50 m<sup>2</sup>||Not applicable||1||0||NA||Yes||None||Yes||None
 
||5 to 50 m<sup>2</sup>||Not applicable||1||0||NA||Yes||None||Yes||None
 
|-
 
|-
|'''[[rainwater harvesting|Cistern]]'''
+
|'''[[rainwater harvesting|Cisterns]]'''
 
|Not applicable
 
|Not applicable
 
|1:1||Not applicable||0||0||0||Yes||None||Yes||None
 
|1:1||Not applicable||0||0||0||Yes||None||Yes||None
Line 51: Line 51:
 
|5:1 to 10:1||Not applicable||1 to 3||5 to 15||0.5 to 6||No||4m- Building Foundation<br>Underground Utilities||No||2 Yr
 
|5:1 to 10:1||Not applicable||1 to 3||5 to 15||0.5 to 6||No||4m- Building Foundation<br>Underground Utilities||No||2 Yr
 
|-
 
|-
|'''[[Bioswale]] (Dry swale)'''
+
|'''[[Bioswales]] (Dry swale)'''
 
|1 (infiltrating); Not applicable (non-infiltrating)
 
|1 (infiltrating); Not applicable (non-infiltrating)
 
|5:1 to 15:1||Underdrain recommended <br> if < 15 mm/hr||1 to 3||5 to 10||0.5 to 6||No (infiltrating); Yes (non-infiltrating)||4m (3m if impermeable liner<br>is used) Building foundation,<br> Underground utilities,<br> Drinking Water Wellhead Protection Areas||No (infiltrating); Yes (non-infiltrating)||2 Yr (infiltrating); None (non-infiltrating)
 
|5:1 to 15:1||Underdrain recommended <br> if < 15 mm/hr||1 to 3||5 to 10||0.5 to 6||No (infiltrating); Yes (non-infiltrating)||4m (3m if impermeable liner<br>is used) Building foundation,<br> Underground utilities,<br> Drinking Water Wellhead Protection Areas||No (infiltrating); Yes (non-infiltrating)||2 Yr (infiltrating); None (non-infiltrating)
Line 59: Line 59:
 
|5:1 to 10:1||Not a constraint||1 to 3||0||< 15%||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||No||2 Yr
 
|5:1 to 10:1||Not a constraint||1 to 3||0||< 15%||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||No||2 Yr
 
|-
 
|-
|'''[[Stormwater Tree Trenches]]'''
+
|'''[[Stormwater Tree Trenches|Stormwater tree trenches]]'''
 
|1  
 
|1  
 
|5:1 to 15:1||[[Underdrain]] recommended<br>if < 15 mm/hr||1 to 2||5 to 10||0 to 2||No||4m- Building Foundation<br>Underground Utilities, <br>Drinking Water Wellhead<br>Protection Areas||No||2 yr
 
|5:1 to 15:1||[[Underdrain]] recommended<br>if < 15 mm/hr||1 to 2||5 to 10||0 to 2||No||4m- Building Foundation<br>Underground Utilities, <br>Drinking Water Wellhead<br>Protection Areas||No||2 yr

Revision as of 18:04, 10 March 2022

Installation type Depth to high water or bedrock (m)[1] Typical ratio of
Impervious drainage area
to treatment facility area
Native soil infiltration rate (mm/hr)[2] Head (m)[3] Space % [4] Slope % [5] Applicable in pollution hotspots [6] Set backs Karst[7] Wellhead protection area[8]
Rain Barrels Not applicable 5 to 50 m2 Not applicable 1 0 NA Yes None Yes None
Cisterns Not applicable 1:1 Not applicable 0 0 0 Yes None Yes None
Roof downspout disconnection Not applicable 5 to 100 m2 Amend if < 15 mm/hr 0.5 5 to 20 1 to 5 Yes Building Foundation Yes None
Infiltration trenches or Infiltration chambers 1 5:1 to 20:1 Not a constraint 1 to 2 0 to 1 <15 % No 4m- Building Foundation
Underground Utilities, Trees,
Drinking Water Wellhead
Protection Areas
No 2 yr
Bioretention 1 (infiltrating); Not applicable (non-infiltrating) 5:1 to 15:1 Underdrain recommended
if < 15 mm/hr
1 to 2 5 to 10 0 to 2 No (infiltrating); Yes (non-infiltrating) 4m- Building Foundation
Underground Utilities, Trees,
Drinking Water Wellhead
Protection Areas
No (infiltrating); Yes (non-infiltrating) 2 yr (infiltrating); None (non-infiltrating)
Stormwater planters Not applicable 5:1 Not a constraint 1 to 2 2 to 5 0 to 2 No (infiltrating); Yes (non-infiltrating) Building Foundation, Trees No (infiltrating); Yes (non-infiltrating) 2 Yr (infiltrating); None (non-infiltrating)
Vegetated filter strips Not applicable 5:1 Amend if < 15 mm/hr 0 to 1 15 to 20 1 to 5 No None Yes None
Permeable pavements 1 (infiltrating); Not applicable (non-infiltrating) 1:1 Underdrain recommended
if < 15 mm/hr
0.5 to 1 0 1 to 5 No (infiltrating); Yes (non-infiltrating) 4m-Underground Utilities
Drinking Water Wellhead
Protection Areas
No (infiltrating); Yes (non-infiltrating) 2 Yr (infiltrating); None (non-infiltrating)
Enhanced swales (featuring check dams) 1 5:1 to 10:1 Not applicable 1 to 3 5 to 15 0.5 to 6 No 4m- Building Foundation
Underground Utilities
No 2 Yr
Bioswales (Dry swale) 1 (infiltrating); Not applicable (non-infiltrating) 5:1 to 15:1 Underdrain recommended
if < 15 mm/hr
1 to 3 5 to 10 0.5 to 6 No (infiltrating); Yes (non-infiltrating) 4m (3m if impermeable liner
is used) Building foundation,
Underground utilities,
Drinking Water Wellhead Protection Areas
No (infiltrating); Yes (non-infiltrating) 2 Yr (infiltrating); None (non-infiltrating)
Exfiltration trenches 1 5:1 to 10:1 Not a constraint 1 to 3 0 < 15% No 4m- Building Foundation
Underground Utilities, Trees,
Drinking Water Wellhead
Protection Areas
No 2 Yr
Stormwater tree trenches 1 5:1 to 15:1 Underdrain recommended
if < 15 mm/hr
1 to 2 5 to 10 0 to 2 No 4m- Building Foundation
Underground Utilities,
Drinking Water Wellhead
Protection Areas
No 2 yr
  1. Minimum depth between the base of the facility and the elevation of the seasonally high water table or top of bedrock
  2. Infiltration rate estimates based on measurements of hydraulic conductivity under field saturated conditions at the proposed location and depth of the practice
  3. Vertical distance between the inlet and outlet of the LID practice
  4. Percent of open pervious land on the site that is required for the LID practice
  5. Slope at the LID practice location
  6. Suitable in pollution hot spots or runoff source areas where land uses or activities have the potential to generate highly contaminated runoff
  7. Suitability in areas of karst geologic formations
  8. | Drinking Water Source Protection wellhead protection area time of travel