Line 5: |
Line 5: |
| *<strong>Micro- or Ultra- filtration</strong> uses such fine membranes that the vast majority of harmful viruses, bacteria etc. are excluded from the water directly. | | *<strong>Micro- or Ultra- filtration</strong> uses such fine membranes that the vast majority of harmful viruses, bacteria etc. are excluded from the water directly. |
| All three water purification technologies require specialist design and consultation with a subject matter expert is recommended for higher tiers of water use. | | All three water purification technologies require specialist design and consultation with a subject matter expert is recommended for higher tiers of water use. |
− |
| |
| {|class="wikitable" | | {|class="wikitable" |
| |+ Water quality treatment required for multi-residential and commercial applications (Abridged from [https://www.iccsafe.org/wp-content/uploads/110116-Draft-CSA_ICC-B805-Rainwater-Harvesting.pdf CSA B805 draft]) | | |+ Water quality treatment required for multi-residential and commercial applications (Abridged from [https://www.iccsafe.org/wp-content/uploads/110116-Draft-CSA_ICC-B805-Rainwater-Harvesting.pdf CSA B805 draft]) |
Line 53: |
Line 52: |
| *Misting stations | | *Misting stations |
| *Swamp coolers}} | | *Swamp coolers}} |
− | |0||99.999%||99.999%||colspan = "3" style="text-align: center; background: orange;"|Outside of the scope of the CSA standard | + | |0||99.999%||99.999%||colspan = "3" style="text-align: center;"|Outside of the scope of the CSA standard |
| |} | | |} |
| + | ===Source Water Quality=== |
| + | A study of many types of roof surfaces in Texas found: |
| + | *'Cool' membrane, concrete tile, and metal roofs all produced water of similar good quality for non-potable use, |
| + | *The runoff water from asphalt shingle and green roofs contained significantly more dissolved organic carbon (DOC). The DOC can add a yellow colour to the water. If the water is treated with chlorine, for drinking purposes, DOC can produce toxic compounds<ref>Mendez CB, Klenzendorf JB, Afshar BR, et al. The effect of roofing material on the quality of harvested rainwater. Water Res. 2011;45(5):2049-2059. doi:10.1016/j.watres.2010.12.015.</ref>. |
| + | Research in Hamilton, ON assessed the water quality of rain collected from three highly reflective 'cool roof' membranes<ref>Cupido, A., B. Baetz, Y. Guo, and A. Robertson. 2012. An evaluation of rainwater runoff quality from selected white roof membranes. doi: 10.2166/wqrjc.2012.011.</ref>. Key findings: |
| + | *The water was free from significant contamination with by-products of plastic manufacture and did not show elevated levels of the five metals tested. |
| + | *Increased microbiological contamination was found in runoff from roof areas where ponding occurred. |
| + | Note: Increased microbiological contamination in roof runoff is also associated with warmer weather <ref>Vialle C, Sablayrolles C, Lovera M, Jacob S, Huau MC, Montrejaud-Vignoles M. Monitoring of water quality from roof runoff: Interpretation using multivariate analysis. Water Res. 2011;45(12):3765-3775. doi:10.1016/j.watres.2011.04.029.</ref>. |
| | | |
− | <h5>Source Water Quality </h5>
| + | ==References== |
− | <p> A study of many types of roof surfaces in Texas found:
| |
− | <ul>
| |
− | <li>'Cool' membrane, concrete tile, and metal roofs all produced water of similar good quality for non-potable use, </li>
| |
− | <li>The runoff water from asphalt shingle and green roofs contained significantly more dissolved organic carbon (DOC). The DOC can add a yellow colour to the water. If the water is treated with chlorine, for drinking purposes, DOC can produce toxic compounds[http://www.sciencedirect.com/science/article/pii/S0043135410008535]. </li>
| |
− | </ul></p>
| |
− | <p> Research in Hamilton, ON assessed the water quality of rain collected from three highly reflective 'cool roof' membranes[http://wst.iwaponline.com/content/70/7/1205?utm_source=TrendMD&utm_medium=cpc&utm_campaign=Water_Science_and_Technology_TrendMD_0]. Key findings:
| |
− | <ul><li>The water was free from significant contamination with by-products of plastic manufacture and did not show elevated levels of the five metals tested. </li>
| |
− | <li>Increased microbiological contamination was found in runoff from roof areas where ponding occurred.</li>
| |
− | </ul>
| |
− | </p>
| |
− | <p>Increased microbiological contamination in roof runoff is also associated with warmer weather[http://www.sciencedirect.com/science/article/pii/S0043135411002181].</p>
| |