Pretreatment features

From LID SWM Planning and Design Guide
Revision as of 18:11, 3 October 2017 by Jenny Hill (talk | contribs)
Jump to navigation Jump to search
Without a forebay (top) the flow is concentrated around the inlet, potentially causing erosion and not optimally spread for infiltration; A three sided forebay (centre) with a level spreader on all sides will distribute the water and reduce the energy, sediment will collect in the pad of the forebay (shown darker); In a narrow cell, the forebay may extend across the whole facility (bottom).

Forebays are a form of pretreatment for open inlet such as curb cuts. Energy of the incoming flow is dissipated, causing suspended particles to drop out of the water. These accumulated particles/sediment can then be easily swept or vacuumed during routine maintenance and doesn't end up clogging downstream filter media or material.
A well designed forebay will also spread the flow somewhat, reducing erosion around the inlet. One effective way of achieving this is by surrounding the pad with some form of level spreader on all sides. The level spreading could be a sharp crested weir in metal or concrete, or be more like a soft edged check dam.