Changes

Jump to navigation Jump to search
no edit summary
Line 1: Line 1:  
[[File:Sizing flow-through planter.jpg|thumb|A flow-through planter comprises a ponding zone, mulch layer, filter media for planting, and a supporting gravel drainage layer]]
 
[[File:Sizing flow-through planter.jpg|thumb|A flow-through planter comprises a ponding zone, mulch layer, filter media for planting, and a supporting gravel drainage layer]]
 +
This article is specific to flow-through [[Stormwater planters|stormwater planters]], vegetated systems that do not infiltrate water to the native soil. <br>
 +
If you are designing a planted system which does infiltrate water, see advice on [[Bioretention: Sizing]].
 +
 +
The dimensions of a stormwater planter are largely predetermined according to the function of the component. As they do not contain a storage reservoir the planters rely more upon careful selection of materials. Both the saturated hydraulic conductivity of the filter media and the number and size of perforations of the [[underdrain]] pipe play critical roles for flow control. Options for maintaining separation between filter media and clear stone aggregate surrounding the perforated pipe include a 100 mm deep choker layer or sheet of geotextile filter fabric.
 +
 +
{| class="wikitable"
 +
|-
 +
! Component
 +
! Recommended depth (with underdrain pipe)
 +
! Typical porosity (''n'')
 +
|-
 +
| Ponding (''d<sub>p</sub>'')
 +
| 150 to 450 mm
 +
| 1
 +
|-
 +
| [[Mulch]]
 +
| 75 ± 25 mm
 +
|
 +
* 0.7 for wood based
 +
* 0.4 for stone
 +
|-
 +
| [[Bioretention: Filter media|Filter media]] (''d<sub>m</sub>'')
 +
|
 +
* 300 mm to support turf grass (and accept only rainwater/roof runoff)
 +
* 600 mm to support shrubs, flowering [[perennials]] and decorative [[grasses]]
 +
* 1000 mm to support [[trees]]
 +
|
 +
* 0.4 for sandier Blend A - Drainage rate priority;
 +
* 0.35 for more loamy Blend B - Water quality treatment priority
 +
|-
 +
| Choker layer
 +
| 100 mm
 +
| 0.4
 +
|-
 +
| Perforated pipe diameter
 +
| 150 to 200 mm
 +
| 0.4
 +
|-
 +
| Clear stone aggregate layer below perforated pipe
 +
| 50 mm (although commonly omitted altogether).
 +
| 0.4
 +
|}

Navigation menu