[[File:Perforated Pipe 550x550.jpg|thumb]]
   
[[File:Perforations.png|thumb|Pipes are available with perforations on just one side, these should be situated on the lower half of the pipe. Pipes with 360° perforations should have a strip of geotextile or membrane placed over the pipe to reduce the migration of fines from overlying media.]]  
 
[[File:Perforations.png|thumb|Pipes are available with perforations on just one side, these should be situated on the lower half of the pipe. Pipes with 360° perforations should have a strip of geotextile or membrane placed over the pipe to reduce the migration of fines from overlying media.]]  
Perforated pipes are a common component of [[underdrains]], [[infiltration trenches]] and [[exfiltration trenches]].   
+
Perforated pipes are a common component of [[underdrains]] used in [[bioretention]], [[permeable pavements]], [[infiltration trenches]] and [[exfiltration trenches| exfiltration systems]].   
   −
Pipes should have been manufactured in conformity with the latest standards by the Canadian Standards Association (CSA) or ASTM International.
+
Pipes should be manufactured in conformity with the latest standards by the Canadian Standards Association (CSA) or ASTM International.
*Perforated pipes should be continuously perforated, smooth interior HDPE (or equivalent material) with a minimum inside diameter of 100 mm.
+
*Perforated pipes should be continuously perforated, smooth interior HDPE or PVC.
 +
**Wherever possible pipes should be ≥200 mm internal diameter to reduce potential of freezing and to facilitate push camera inspections and cleaning with jet nozzle equipment.  
 
**Smooth interior facilitates inspection and maintenance activities; internal corrugations can cause cameras or hydrojetting apparatus to become snagged.     
 
**Smooth interior facilitates inspection and maintenance activities; internal corrugations can cause cameras or hydrojetting apparatus to become snagged.     
*Where freezing is a concern, horizontal underdrain pipes should be over-sized to a minimum 200 mm diameter.
  −
*Perforations should be made on all sides of the pipe and provide a ≥ 1 m<sup>2</sup> of open area per linear meter of pipe.
   
**A perforated pipe with many rectangular slots has better drainage characteristics than a pipe with similar open area provided by fewer circular holes <ref>Hazenberg, G., and U. S. Panu (1991), Theoretical analysis of flow rate into perforated drain tubes, Water Resour. Res., 27(7), 1411–1418, doi:10.1029/91WR00779.</ref>.
 
**A perforated pipe with many rectangular slots has better drainage characteristics than a pipe with similar open area provided by fewer circular holes <ref>Hazenberg, G., and U. S. Panu (1991), Theoretical analysis of flow rate into perforated drain tubes, Water Resour. Res., 27(7), 1411–1418, doi:10.1029/91WR00779.</ref>.
*Non-perforated pipes should be used for conveyance to and away from the facility, including overflow.
+
*Non-perforated pipes should be used for conveyance of stormwater to and from the facility, including [[overflow]]. It is good practice to extend the solid pipe approximately 300 mm within the reservoir or practice to reduce the potential for native soil migration into the pipe.
 +
 
 +
<gallery mode="packed" widths=200px heights=200px>
 +
Perforated Pipe 550x550.jpg|Pipe with slotted perforations
 +
Pipe with connector.jpg|Perforated pipes awaiting installation, note the 45 degree couplings used to facilitate push camera inspection and jet nozzle cleaning.
 +
</gallery>
 +
See also: [[Flow through perforated pipe]]
 
----   
 
----   
 
[[Category:Materials]]
 