Line 4: |
Line 4: |
| {{TOClimit|2}} | | {{TOClimit|2}} |
| ==Overview== | | ==Overview== |
| + | {{float right|{{#widget:YouTube|id=DLXsb1FwKD4}}}} |
| As their name suggests infiltration trenches work primarily to infiltrate and convey stormwater. They are an underground facility and are excellently suited to connecting other components in the treatment train. | | As their name suggests infiltration trenches work primarily to infiltrate and convey stormwater. They are an underground facility and are excellently suited to connecting other components in the treatment train. |
| {{textbox|1=Infiltration trenches are an ideal technology for: | | {{textbox|1=Infiltration trenches are an ideal technology for: |
Line 17: |
Line 18: |
| | | |
| ==Design== | | ==Design== |
− | {{float right|{{#widget:YouTube|id=DLXsb1FwKD4}}}}
| |
| ===Sizing=== | | ===Sizing=== |
| '''[[Infiltration: Sizing and modeling]]''' | | '''[[Infiltration: Sizing and modeling]]''' |
− | | + | *Virginia up to 10' (3 m) deep. <ref>Viriginia Department of Transport. (2010). VDOT BMP Design Manual of Practice. Retrieved March 15, 2018, from http://www.virginiadot.org/business/resources/LocDes/BMP_Design-Manual/Chapter_8_Infiltration_Trench.pdf</ref> |
− | Virginia up to 10' (3 m) deep. <ref>Viriginia Deprtmant of Transport. (2010). VDOT BMP Design Manual of Practice. Retrieved March 15, 2018, from http://www.virginiadot.org/business/resources/LocDes/BMP_Design-Manual/Chapter_8_Infiltration_Trench.pdf</ref> | + | *Minnesota up to 12' (3.6 m) deep. <ref>Design criteria for Infiltration trench. (2016, September 21). Minnesota Stormwater Manual, . Retrieved 13:25, April 4, 2018 from https://stormwater.pca.state.mn.us/index.php?title=Design_criteria_for_Infiltration_trench&oldid=28702.</ref> |
− | Minnesota up to 12' (3.6 m) deep. <ref>Design criteria for Infiltration trench. (2016, September 21). Minnesota Stormwater Manual, . Retrieved 13:25, April 4, 2018 from https://stormwater.pca.state.mn.us/index.php?title=Design_criteria_for_Infiltration_trench&oldid=28702.</ref> | + | *"...not normally be deeper than 3 to 4 m in order to maximise the length of the flow path to the water table through the unsaturated zone." <ref>Design of soakaways (2015) www.tiipublications.ie/library/DN-DNG-03072-01.pdf</ref> |
| + | *There is a cost implication with digging deeper practices, trench boxes may be required to retain the side walls during construction. |
| | | |