Line 44:
Line 44:
<math>P=\frac{IiD}{nd+qD}</math>
<math>P=\frac{IiD}{nd+qD}</math>
+
<h3>Drawdown time</h3>
+
The design of infiltration facilities should be checked for [[drawdown time]]. Target drawdown time is between 48-72 hours.
To calculate the time (''t'') to fully drain the facility:
To calculate the time (''t'') to fully drain the facility:
<math>t=\frac{nd}{q}</math>