The rearrangement to calculate the required footprint area of the facility for a given depth is not available at this time. Elegant submissions are invited.  
 
The rearrangement to calculate the required footprint area of the facility for a given depth is not available at this time. Elegant submissions are invited.  
    +
<h3>Drawdown time</h3>
 +
The design of infiltration facilities should be checked for [[drawdown time]]. Target drawdown time is between 48-72 hours.
 
To calculate the time (''t'') to fully drain the facility:  
 
To calculate the time (''t'') to fully drain the facility:  
 
<math>t=\frac{nP}{qx}ln\left [ \frac{\left (d+ \frac{P}{x} \right )}{\left(\frac{P}{x}\right)}\right]</math>
 
<math>t=\frac{nP}{qx}ln\left [ \frac{\left (d+ \frac{P}{x} \right )}{\left(\frac{P}{x}\right)}\right]</math>