Changes

Jump to navigation Jump to search
Line 53: Line 53:     
This spreadsheet tool has been set up to perform all of the infiltration practice sizing calculations shown below<br>
 
This spreadsheet tool has been set up to perform all of the infiltration practice sizing calculations shown below<br>
{{Clickable button|[[Media:Infiltration Sizing 20220617 locked.xlsx|Download the infiltration practice sizing tool]]}}
+
{{Clickable button|[[Media:Infiltration Sizing 20220617 locked (1).xlsx|Download the infiltration practice sizing tool]]}}
    
==To calculate the required storage reservoir footprint area where the depth is fixed or constrained (1D drainage)==
 
==To calculate the required storage reservoir footprint area where the depth is fixed or constrained (1D drainage)==
Line 113: Line 113:  
<math>t=\frac{n\times A_{r}}{f'\times x}ln\left [ \frac{\left (d_{r} + \frac{A_{r}}{x} \right)}{\left (\frac{A_{r}}{x}\right) }\right]</math>
 
<math>t=\frac{n\times A_{r}}{f'\times x}ln\left [ \frac{\left (d_{r} + \frac{A_{r}}{x} \right)}{\left (\frac{A_{r}}{x}\right) }\right]</math>
 
Where "ln" means natural logarithm of the term in square brackets <br>
 
Where "ln" means natural logarithm of the term in square brackets <br>
Adapted from CIRIA, The SUDS Manual C753 (2015).
+
Adapted from CIRIA, The SUDS Manual C753 (2015)<ref>Construction Industry Research and Information Association (CIRIA). 2015. The SUDS Manual C753. Accessed: 18 November 2021. https://www.ciria.org/CIRIA/Memberships/The_SuDs_Manual_C753_Chapters.aspx</ref>
    