Changes

Jump to navigation Jump to search
m
no edit summary
Line 1: Line 1: −
{{Clickable button|[[File:TTT.png|400 px|link=http://www.sustainabletechnologies.ca/wp/low-impact-development-treatment-train-tool/]]}}
+
[[File:Storage TTT.png|thumb|[[Dry ponds]] are found in storage element in the LID TTT]]
[[File:Storage TTT.png|thumb|[[Dry ponds]] are found in storage element in the LID TTT.]]
+
[[File:Pond curves.png|thumb|The largest area is at the top, level 0 m; each subsequent lower depth has a smaller area]]
 
+
{{Clickable button|[[File:TTT.png|350 px|link=http://www.sustainabletechnologies.ca/wp/low-impact-development-treatment-train-tool/]]}}
Dry ponds are a storage element in the Treatment Train Tool.
+
 
{|class="wikitable"
 
{|class="wikitable"
|+A [[Dry ponds|Dry pond]] as a storage element (key parameters)
+
|+A [[Dry ponds|dry pond]] as a storage element (key parameters) in the Treatment Train Tool.
 
|-
 
|-
 
!colspan = "2"|Stage Storage
 
!colspan = "2"|Stage Storage
 
|-
 
|-
|Name||Important to have a unique name, to associate with the subcatchment (harvesting area)
+
|Name||Important to have a unique name, to connect it with the catchment area
 
|-
 
|-
|Storage type||No removal
+
|Storage type||Dry detention ponds
 
|-
 
|-
|Bottom elevation (m)||This will be 0 for installations at ground level, but will often be underground. This is of greater importance when the overflow is coupled to another component within a treatment train
+
|Bottom elevation (m)||This is important to correspond with other components, <br>e.g. when the overflow is coupled to another BMP within a treatment train
 
|-
 
|-
|Maximum depth (m)||Height of the RWH cistern
+
|Maximum depth (m)||
 
|-
 
|-
|Lined/unlined||Lined
+
|Lined/unlined||Unlined (ideally)
 
|-
 
|-
|Evaporation factor||0
+
|Underlying soil||Choose from five; sandy soils drain more quickly.
 +
|-
 +
|Evaporation factor||?
 
|-
 
|-
!colspan = "2" style="background: darkcyan; color: white; align = center"|Curves
+
|Suction head (mm)||?
 
|-
 
|-
|colspan = 2|The Curves table is designed to accommodate ponds of roughly conical dimensions. Rainwater cistern are usually cuboid or cylindrical in shape, so that the area (m<sup>2</sup>) will remain the same throughout the depth. The top and bottom dimensions can be placed within the first two rows of the table.  
+
|Saturated conductivity (mm/hr)||?
 +
|-
 +
|Initial soil moisture deficit (fraction)||?
 +
|-
 +
!colspan = "2" align = center"|Curves
 +
|-
 +
|colspan = 2|The Curves table is designed to accommodate the side slopes. The top line begins at 0 m, with subsequent depths in the following lines.  
 
|}
 
|}