Changes

Jump to navigation Jump to search
m
Line 6: Line 6:     
==Design==
 
==Design==
<h3>Sizing</h3>
+
===Sizing===
The surface storage volume of a dry pond (''A<sub>p</sub>'') is simply determined:
+
The surface storage volume of a dry pond (''A<sub>p</sub>'') is determined:
 
   
 
   
 
<math>A_{p}=\frac{RVC_T\times A_{c}}{q\times t_{drawdown}}</math>
 
<math>A_{p}=\frac{RVC_T\times A_{c}}{q\times t_{drawdown}}</math>
Line 14: Line 14:  
*''RVC<sub>T</sub>'' = [[Runoff volume control target]] (mm)
 
*''RVC<sub>T</sub>'' = [[Runoff volume control target]] (mm)
 
*''A<sub>c</sub>'' = Area of the catchment (m<sup>2</sup>)
 
*''A<sub>c</sub>'' = Area of the catchment (m<sup>2</sup>)
*''q'' = infiltration rate (mm/hr)
+
*''f''' = design infiltration rate (mm/hr)
 
*''t'' = [[drawdown time]] (hrs)}}
 
*''t'' = [[drawdown time]] (hrs)}}
  