Changes

Jump to navigation Jump to search
m
no edit summary
Line 1: Line 1:  
The following, comprehensive list is presented as a basis for discussion between regulatory authorities and design practitioners.
 
The following, comprehensive list is presented as a basis for discussion between regulatory authorities and design practitioners.
 
+
{{TOClimit|2}}
 
==Site Description==
 
==Site Description==
 
* Location (key plan, municipal address, nearest roads, watershed and subwatershed);
 
* Location (key plan, municipal address, nearest roads, watershed and subwatershed);
Line 33: Line 33:  
**LID facility location and associated tributary areas;
 
**LID facility location and associated tributary areas;
 
* Model schematics;
 
* Model schematics;
* Storm drainage, grading and general servicing plans;
+
* Storm drainage, [[grading]] and general servicing plans;
 
* LID practice design [[drawings]] and details;
 
* LID practice design [[drawings]] and details;
 
* [https://sustainabletechnologies.ca/home/erosion-and-sediment-control/ Erosion and sediment control plans];
 
* [https://sustainabletechnologies.ca/home/erosion-and-sediment-control/ Erosion and sediment control plans];
Line 60: Line 60:  
| x
 
| x
 
|  
 
|  
| shown on plan view and typical details provided (curb cut, flow spreader, ribbon curb)
+
| shown on plan view and typical details provided ([[curb cuts]], [[level spreader|flow spreader]], ribbon curb)
 
|-
 
|-
 
| Materials
 
| Materials
Line 68: Line 68:  
| Materials specs (soil, drainage layer), depth, hydraulic conductivity, porosity
 
| Materials specs (soil, drainage layer), depth, hydraulic conductivity, porosity
 
|-
 
|-
| Vegetaion
+
| Vegetation
 
| x
 
| x
 
| x
 
| x
 
|  
 
|  
| Planting plan and vegetation details (species, mature density, succession plan)
+
| Planting plan and [[vegetation]] details (species, mature density, succession plan)
 
|-
 
|-
 
| Outlet
 
| Outlet
Line 78: Line 78:  
| x
 
| x
 
| x
 
| x
| Underdrain spec and slope, spill elevation, catch basin type and grate, weir type and lcoation, inlet control device details
+
| [[Underdrain]] spec and slope, spill elevation, catch basin type and grate, [[weir]] type and location, [[inlet]] control device details
 
|-
 
|-
 
| Catchment
 
| Catchment
Line 84: Line 84:  
|  
 
|  
 
|  
 
|  
| Delineated catchment area directed to bioretention facility
+
| Delineated catchment area directed to [[bioretention]] facility
 
|-
 
|-
 
| Subsurface materials
 
| Subsurface materials
Line 90: Line 90:  
| x
 
| x
 
|  
 
|  
| Layer oder (filter, reservoir, geotextiles (if using)) and specifications (gradation, hydraulic condcutivity, void space)
+
| Layer order (filter, [[reservoir aggregate|reservoir]], [[choker course]], [[geotextiles]] (if using)) and specifications (gradation, hydraulic conductivity, void space)
 
|-
 
|-
 
| Depth
 
| Depth
Line 114: Line 114:  
| x
 
| x
 
|  
 
|  
| Ponding depth and water surface elevation durign deisgn storm and maximum prior to overflow
+
| Ponding depth and water surface elevation during design storm and maximum prior to [[overflow]]
 
|-
 
|-
 
| Inundation
 
| Inundation
Line 154: Line 154:  
*External drainage conveyance (100 year and Regional);
 
*External drainage conveyance (100 year and Regional);
 
===Quality control===
 
===Quality control===
*Level of Protection;
+
*Level of protection;
*Drainage Area to Facility in hectares;
+
*Drainage area to facility in hectares;
*Percentage Impervious – total and directly connected areas;
+
*Percentage impervious – total and directly connected areas;
*SWM Facility Monitoring and Maintenance Requirements;
+
*SWM facility monitoring and maintenance requirements;
    
==Hazard land management==
 
==Hazard land management==
8,255

edits