Curb cuts

From LID SWM Planning and Design Guide
Revision as of 00:56, 29 September 2017 by Jenny Hill (talk | contribs)
Jump to navigation Jump to search


Sizing[edit]

To completely capture linear flow travelling along a gutter perpendicular to a curb inlet, the inlet must be of width:: Failed to parse (MathML with SVG or PNG fallback (recommended for modern browsers and accessibility tools): Invalid response ("Math extension cannot connect to Restbase.") from server "https://wikimedia.org/api/rest_v1/":): {\displaystyle W_T=0.817Q^{0.42}S_{0}^{0.3}\left (\frac{1}{nS_{x}}\right)^{0.6}}

Where the intention is to capture only a proportion of the flow, the ratio of flow entering the crub inlet may be calculated:: Failed to parse (MathML with SVG or PNG fallback (recommended for modern browsers and accessibility tools): Invalid response ("Math extension cannot connect to Restbase.") from server "https://wikimedia.org/api/rest_v1/":): {\displaystyle R_c=1-\left ( 1-\frac{W}{W_T} \right )^{1.8}}

Example[edit]

Curb cuts Gallery[edit]