Changes

Jump to navigation Jump to search
m
Line 2: Line 2:  
For underground conveyance which promotes infiltration, see [[Exfiltration trenches]]. <br>
 
For underground conveyance which promotes infiltration, see [[Exfiltration trenches]]. <br>
 
For design recommendations on channels in which surface flow is controlled with [[check dams]], see [[Enhanced swales]].
 
For design recommendations on channels in which surface flow is controlled with [[check dams]], see [[Enhanced swales]].
 +
{{TOClimit|2}}
 
==Overview==
 
==Overview==
 
'''The fundamental components of a bioswale are:'''
 
'''The fundamental components of a bioswale are:'''
Line 14: Line 15:  
==Planning considerations==
 
==Planning considerations==
 
Bioswales are sized as narrow linear [[bioretention cells]].  
 
Bioswales are sized as narrow linear [[bioretention cells]].  
[[Drainage time]] of bioswales are typically lower than other geometric configurations of similarly sized bioretention facilities, owing to the higher hydraulic radius of the sides.  
+
[[Drainage time]] of bioswales is typically lower than other geometric configurations of similarly sized bioretention facilities, owing to the higher hydraulic radius of the sides.
    
==Design==
 
==Design==
Line 23: Line 24:  
{{:Overflow}}
 
{{:Overflow}}
 
==Materials==
 
==Materials==
 +
All forms of bioretention are complex in their structure, so please follow separate links for the materials.
 +
*[[Plants]] and [[Planting design]]
 
*[[Bioretention: Filter media]]
 
*[[Bioretention: Filter media]]
{{:Plant lists}}
+
*[[Choker layer]]
*See also [[Planting design]]
+
*[[Underdrains]]
    
==Gallery==
 
==Gallery==
 
{{:Bioswales: Gallery}}
 
{{:Bioswales: Gallery}}
 +
 +
==Planting Design Considerations==
 +
*Where possible a combination of native trees, shrubs and perennial herbs should be used in addition to grasses.
 +
*Most bioswales will be situated to receive full sun exposure. The ‘Exposure’ column in the master plant list identifies the sun exposure condition for each species.
 +
*Facilities with a deeper media bed (greater than 1 m) provide the opportunity for a wider range of plant species (including trees).
 +
*For applications along roads and parking lots, where snow may be plowed or stored, non-woody and salt tolerant species should be chosen.
 +
*Proper spacing must be provided for aboveground and below ground utilities, and adjacent infrastructure.
    
==Performance==
 
==Performance==
 
{{:Bioswales: Performance}}
 
{{:Bioswales: Performance}}
101

edits

Navigation menu