Changes

Jump to navigation Jump to search
Line 126: Line 126:  
*f<sub>f, min</sub> = minimum infiltration rate (i.e. saturated hydraulic conductivity) of the filter media (m/h), see [[Bioretention: Filter media|Filter media]] for guidance}}<br>
 
*f<sub>f, min</sub> = minimum infiltration rate (i.e. saturated hydraulic conductivity) of the filter media (m/h), see [[Bioretention: Filter media|Filter media]] for guidance}}<br>
 
For practices where flow is delivered directly to the storage reservoir:
 
For practices where flow is delivered directly to the storage reservoir:
<math>A_{p}=i\times D\times A_{i}/[d_{a} + (f' \times D)]</math>
+
<math>A_{p}=i\times D\times A_{i}/[d_{i} + (f' \times D)]</math>
 
{{Plainlist|1=Where:
 
{{Plainlist|1=Where:
*d<sub>a</sub> = Active water storage depth (m), see above for equations for with and without underdrain designs
+
*d<sub>i</sub> = Infiltration water storage depth (m), see above for equations for with and without underdrain designs
 
*f' = design infiltration rate of the underlying native soil (m/h)
 
*f' = design infiltration rate of the underlying native soil (m/h)
 
*D = Design storm duration (h)}}<br>
 
*D = Design storm duration (h)}}<br>