[[File:Jet cleaning.jpg|thumb|Diagram of hydrojetting cleaning apparatus]]
[[File:Jet cleaning.jpg|thumb|Diagram of hydrojetting cleaning apparatus]]
−
To permit access by cameras or cleaning apparatus, 90 degree connector must not be used in underdrains. Instead 2 x 45 degree couplers, or preferably 3 x 30 degree couplers should be used instead. For the same reason, dual walled perforated pipes with smooth internal walls are necessary.
+
To permit access by cameras or cleaning apparatus, 90 degree connectors must not be used in subterranean underdrains. Instead 2 x 45 degree connectors, or preferably 3 x 30 degree connectors should be used instead.
+
+
For the same reason, dual walled perforated pipes with smooth internal walls are necessary to reduce the potential snagging of maintenance equipment.
+
===Wells===
*[[Wells]], of 100 - 150 mm diameter perforated pipe, should extend to the bottom of the facility.
*[[Wells]], of 100 - 150 mm diameter perforated pipe, should extend to the bottom of the facility.
*The exposed tops of all wells should be fitted with lockable caps.