Line 1: |
Line 1: |
| {{float right|<pdf width="500" height="600">File:TO curb.pdf</pdf>}} | | {{float right|<pdf width="500" height="600">File:TO curb.pdf</pdf>}} |
− | Whilst we consider preparing our own set of STEP LID drawings, we are providing a quick reference list to DWG files from others (including proprietary systems). | + | Whilst we consider preparing our own set of STEP LID drawings, we are providing a quick reference list to drawing files from others (including proprietary systems). |
| | | |
− | If you want help in finding example detailed drawings for an LID installation, please email STEP or use the comment box below. | + | If you want help in finding example details for an LID design, please email STEP or use the comment box below. |
| {{textbox| 1= | | {{textbox| 1= |
− | You know that typical drawings are no substitute for engineered design!}} | + | You know that typical drawings are no substitute for properly configured design!}} |
| | | |
| ==Ontario Municipal== | | ==Ontario Municipal== |
− | *[https://www.toronto.ca/services-payments/streets-parking-transportation/enhancing-our-streets-and-public-realm/green-streets/ City of Toronto] See exmaple of [[curb extensions]] to the right. | + | *The [https://www.toronto.ca/services-payments/streets-parking-transportation/enhancing-our-streets-and-public-realm/green-streets/ City of Toronto] Green Streets program included production of many drawn'typicals'. See example of [[curb extensions]] to the right.<ref>https://www.toronto.ca/services-payments/streets-parking-transportation/enhancing-our-streets-and-public-realm/green-streets/</ref> |
| + | *The City of Kitchener has standard details for [https://www.kitchener.ca/en/resourcesGeneral/Documents/DSD_ENG_C-of-K---Standard-Specifications_November-2017.pdf pervious concrete pavement, precast permeable interlocking pavement and permeable pipe exfiltration systems]<ref>https://www.kitchener.ca/en/resourcesGeneral/Documents/DSD_ENG_C-of-K---Standard-Specifications_November-2017.pdf</ref>. |
| + | *The City of Barrie has a draft standard detail for [https://www.barrie.ca/City%20Hall/environmental-assessment-studies/Documents/Drainage-Master-Plan/1%20-%20Draft%20Drainage%20Master%20Plan%20%28without%20figures%29.pdf an exfiltration trench] on page 125 of the linked document. '''Note''' that the 'within-WHPA' detail is not supported by STEP.<ref>https://www.barrie.ca/City%20Hall/environmental-assessment-studies/Documents/Drainage-Master-Plan/1%20-%20Draft%20Drainage%20Master%20Plan%20%28without%20figures%29.pdf</ref> |
| | | |
| ==Elsewhere== | | ==Elsewhere== |
− | *[http://extension.oregonstate.edu/stormwater/standard-details Oregon State University LID typicals by GreenGirl] | + | *[http://extension.oregonstate.edu/stormwater/standard-details Oregon State University LID typicals] by GreenGirl |
| + | *[https://www.lid-stormwater.net/design_examples.htm Plan drawings] by Low Impact Development Center, Inc. |
| + | *[https://www.pwdplanreview.org/upload/pdf/PWD_Stormwater_Details_Bioinfiltration_Bioretention_Basin.dwg Bioretention detail] by Philly Water |
| + | *[https://www.pwdplanreview.org/upload/pdf/PWD_Stormwater_Details_Porous_Pavement.dwg Permeable paving] by Philly Water |
| + | *[https://www.pwdplanreview.org/upload/pdf/PWD_Stormwater_Details_Subsurface_Infil_Basin.dwg Pipe-in-stone infiltration] by Philly Water |
| | | |
| ==Proprietary== | | ==Proprietary== |
| {{:Disclaimer}} | | {{:Disclaimer}} |
| *[http://www.ads-pipecanada.ca/en/documentlisting.asp?documenttypeID=5 ADS pipe] | | *[http://www.ads-pipecanada.ca/en/documentlisting.asp?documenttypeID=5 ADS pipe] |
| + | *[http://www.deeproot.com/products/silva-cell/resources.html Soil cells] by Silvacell |
| + | *[https://www.hydro-int.com/en/resources/first-defense-dwg-drawings pretreatment] by Hydro International |
| + | ---- |