''K<sub>media</sub> is expressed in m/day
 
''K<sub>media</sub> is expressed in m/day
 
''D<sub>d</sub>'' is the depth to the drain pipe (m)
 
''D<sub>d</sub>'' is the depth to the drain pipe (m)
''D<sub>w</sub>'' is the minimum acceptable depth to the water table during infiltration
+
''D<sub>w</sub>'' is the minimum acceptable depth to the water table during infiltration event
 
''q'' is the inflow volume expressed as a depth over the entire surface (m)
 
''q'' is the inflow volume expressed as a depth over the entire surface (m)
 
===Example===
 
===Example===
 
During a 25 mm storm event, a bioretention cell receives concentrated flow from a catchment 20 times larger than its own footprint (25 x 20 = 500 mm = 0.5 m).  
 
During a 25 mm storm event, a bioretention cell receives concentrated flow from a catchment 20 times larger than its own footprint (25 x 20 = 500 mm = 0.5 m).  
The bioretention cell comprises 0.6 m filter media laid over 0.6 m clear, coarse reservoir gravel. The pipes are laid within the reservoir, 0.9 m below the surface
+
The bioretention cell comprises 0.6 m filter media laid over 0.6 m clear, coarse reservoir gravel. The pipes are laid within the reservoir, 0.9 m below the surface.
<math>Drain\ spacing=\sqrt{\frac{4\times 2.4m\left(0.9m-0.6m\right)^{2}}{0.5}}=3.4 m</math>
+
The system is designed to fill entirely during the rainstorm event. i.e. Depth to water table = 0 m.   
 +
<math>Drain\ spacing=\sqrt{\frac{4\times 2.4m\left(0.9m-0m\right)^{2}}{0.5}}=6 m</math>
    
==Recommendations for material specifications==
 
==Recommendations for material specifications==