Changes

Jump to navigation Jump to search
m
no edit summary
Line 1: Line 1:  
<poem>
 
<poem>
 
For advice on decorative surface aggregates see [[Stone]]
 
For advice on decorative surface aggregates see [[Stone]]
Gravel for underdrains and underground infiltration structures should be 20 - 50 mm, uniformly-graded, clean (maximum wash loss of 0.5%), crushed angular stone that has a void ratio of 0.4 (40%)<ref>Porosity of Structural Backfill, Tech Sheet #1, Stormtech, Nov 2012, http://www.stormtech.com/download_files/pdf/techsheet1.pdf accessed 16 October 2017 </ref>.
+
 
 +
Gravel used for underdrains and underground infiltration structures should be 20 - 50 mm, uniformly-graded, clean (maximum wash loss of 0.5%), crushed angular stone that has a void ratio of 0.4 (40%)<ref>Porosity of Structural Backfill, Tech Sheet #1, Stormtech, Nov 2012, http://www.stormtech.com/download_files/pdf/techsheet1.pdf accessed 16 October 2017 </ref>.
 +
 
 
The uniform grading and the angularity are important to maintain pore throats and clear voids between particles. (i.e. achieve the void ratio).  
 
The uniform grading and the angularity are important to maintain pore throats and clear voids between particles. (i.e. achieve the void ratio).  
The clean wash is to prevent rapid accumulation of fines in the base of the reservoir.   
+
The clean wash to prevent rapid accumulation of fines from the aggregate particles in the base of the reservoir.   
    
Gravel with structural requirements should also meet the following criteria:
 
Gravel with structural requirements should also meet the following criteria:
8,255

edits