==Sizing==
 
==Sizing==
L=0.817Q^{0.42}S_{0}^{0.3}\left (\frac{1}{nS_{x}}\right)^{0.6}
+
To copmletely capture linear flow travelling along a gutter perpendicular to a curb inlet, the inlet must be of width:
 +
<math>W=0.817Q^{0.42}S_{0}^{0.3}\left (\frac{1}{nS_{x}}\right)^{0.6}</math>
     
8,255