Line 1: |
Line 1: |
| {|class="wikitable" | | {|class="wikitable" |
− | |+ specifications for pervious concrete, porous asphalt, and permeable pavers. | + | |+ <h2>[[Specifications for pervious concrete, porous asphalt, and permeable pavers]] </h2> |
| | | |
| |- | | |- |
Line 9: |
Line 9: |
| | | |
| !Pervious Concrete | | !Pervious Concrete |
− | |* 28 day compressive strength = 5.5 to 20 MPa <br> * Void ratio = 14% - 31%<br>* Permeability = 900 - 21,500 mm/hr||Thickness will range from 100-150 mm depending on the expected loads | + | |* 28 day compressive strength = 5.5 to 20 MPa <br> * Void ratio = 14% - 31%<br>* Permeability = 900 - 21,500 mm/hr||Thickness will range from 100 mm-150 mm depending on the expected loads |
| |- | | |- |
| !Porous Asphalt | | !Porous Asphalt |
| + | |* open-graded asphalt mix with a minimum of 16% air voids <br> * Polymer can be added to provide additional strength to heavy loads||Thickness will range from 50 mm-100 mm depending on the expected loads |
| + | |- |
| + | !Permeable Pavers |
| + | |*ASTM No. 8(5 mm dia) crused aggregate is recommended for fill material in the paver openings.<br>*Pavers shall meet the minimum material and standard specification for Precast Concrete Pavers.<br>*Pigment in concrete pavers shall conform to ASTM C 979 ACI Report No. 212.3R provides guidance on the use of pigments.<br>*Maximum allowable breakage of product is 5%||*For vehicle applications the minimum paver thickness is 80 mm<br>*For pedestrian applications is 60 mm and Joint widths should be no greater than 15 mm. |
| + | |- |