===To calculate the invert of the underdrain from the base of the reservoir===
 
===To calculate the invert of the underdrain from the base of the reservoir===
   −
For designs that include an underdrain, the depth of the storage reservoir below the invert of the underdrain pipe (''d<sub>r, max</sub>'') can be calculated as follows:  
+
For designs that include an underdrain, the depth of the storage reservoir below the invert of the underdrain pipe (''d<sub>r'') can be calculated as follows:  
 
<math>d_{r}=\frac{f'\times t}{n}</math>
 
<math>d_{r}=\frac{f'\times t}{n}</math>
 