Line 128: |
Line 128: |
| <math>A_{p}=i\times D\times A_{i}/[d_{a} + (f' \times D)]</math> | | <math>A_{p}=i\times D\times A_{i}/[d_{a} + (f' \times D)]</math> |
| {{Plainlist|1=Where: | | {{Plainlist|1=Where: |
− | *d<sub>a</sub> = Active water storage depth (m) | + | *d<sub>a</sub> = Active water storage depth (m), see above equations |
− | *n' = effective porosity of the active storage fill material(s), (effective porosity of surface ponding depth and filter media depth combined for practices with no underdrain; porosity of storage reservoir aggregate or effective porosity of void-producing structure system for practices with an underdrain)
| |
| *f' = design infiltration rate of the underlying native soil (m/h) | | *f' = design infiltration rate of the underlying native soil (m/h) |
| *D = Design storm duration (h)}}<br> | | *D = Design storm duration (h)}}<br> |
| * Step 11: Compare required surface area of the practice to available space.<br> | | * Step 11: Compare required surface area of the practice to available space.<br> |
| To decrease A<sub>p</sub>, consider increasing ponding depth if feasible and would not create a safety hazard, or decreasing catchment impervious area. | | To decrease A<sub>p</sub>, consider increasing ponding depth if feasible and would not create a safety hazard, or decreasing catchment impervious area. |
− | * Step 12: Calculate catchment impervious area to practice permeable (footprint) area ratio: | + | * Step 12: Calculate catchment impervious area to practice permeable (footprint) area ratio, R, also referred to as I/P ratio: |
| <math>R=A_{i}/A_{p}</math><br> | | <math>R=A_{i}/A_{p}</math><br> |
| Adjust either A<sub>i</sub> or A<sub>p</sub> to keep R between 5 and 20. | | Adjust either A<sub>i</sub> or A<sub>p</sub> to keep R between 5 and 20. |