Search results
Jump to navigation
Jump to search
Page title matches
- [[File:Perc_test.png|thumb|Schematic of percolation test setup]] ...[design infiltration rate]]. If a site disturbance must be minimized, this test can be performed in a small augered well. Adding a [[permeameter]] may spee7 KB (1,120 words) - 20:15, 27 September 2022
- 3 KB (538 words) - 14:24, 30 April 2019
- 46 bytes (5 words) - 20:04, 12 October 2022
- [[file: Jar_test.jpg|thumb|Steps in conducting a jar test to detect fines in construction materials]] A simple jar test can be used to gauge the proportion of fines in an aggregate product before2 KB (264 words) - 15:57, 13 June 2018
- #REDIRECT [[Percolation test]]30 bytes (3 words) - 14:17, 10 October 2018
- ...structure and Services, 2014. A step-by-step approach known as the 'Ribbon Test" used to help assess soil textures in a collected sample with varying layer480 bytes (73 words) - 21:25, 24 November 2023
Page text matches
- #REDIRECT [[Percolation test]]30 bytes (3 words) - 14:17, 10 October 2018
- *Used to identify potential BMP types, locations and soil test locations; '''2. [[Groundwater|Test Pit or Soil Boring Observations]]'''3 KB (453 words) - 14:22, 20 June 2022
- [[file: Jar_test.jpg|thumb|Steps in conducting a jar test to detect fines in construction materials]] A simple jar test can be used to gauge the proportion of fines in an aggregate product before2 KB (264 words) - 15:57, 13 June 2018
- ...structure and Services, 2014. A step-by-step approach known as the 'Ribbon Test" used to help assess soil textures in a collected sample with varying layer480 bytes (73 words) - 21:25, 24 November 2023
- [[File:Perc_test.png|thumb|Schematic of percolation test setup]] ...[design infiltration rate]]. If a site disturbance must be minimized, this test can be performed in a small augered well. Adding a [[permeameter]] may spee7 KB (1,120 words) - 20:15, 27 September 2022
- flood-test-bioretention.jpg | Flood test for a bioretention LID facility. (Photo Source: CVC, n.d.) Flood-test-permeable-pavers.jpg | Flood test for permeable pavers. (Photo Source: CVC, 2013)4 KB (557 words) - 19:07, 11 March 2024
- ...rticle-size distribution (PSD) test. Other commonly used terms for the PSD test by soil laboratories are “Particle-Size Analysis”, “Grain-Size Distri ...org/Standards/D6913.htm </ref> and ASTM D7928 <ref>ASTM D7928-17, Standard Test Methods for Particle Size Distribution (Gradation) of Fine-Grained Soils Us4 KB (572 words) - 21:05, 8 March 2018
- ...inciple to maintain a steady water level (fixed head condition) within the test well. *Water container (will water need transporting to the test site?)4 KB (573 words) - 19:29, 25 October 2022
- {{:Jar test}}442 bytes (52 words) - 19:19, 12 June 2018
- *[[Percolation test]] ...ced a free online module to provide some basic information on infiltration test methods. Access it [https://sustainabletechnologies.ca/events/design-infilt6 KB (871 words) - 12:41, 14 June 2024
- flood-test-bioretention.jpg | Flood test for a bioretention LID facility. (Photo Source: CVC, n.d.) Flood-test-permeable-pavers.jpg | Flood test for permeable pavers. (Photo Source: CVC, 2013)5 KB (671 words) - 19:15, 28 October 2022
- ...A23.2-09 (R2014)] "Concrete materials and methods of concrete construction/Test methods and standard practices for concrete", and1 KB (156 words) - 21:42, 8 February 2022
- # Choose or create clear, level ground at the desired test location. # Work with minimal disturbance to the soil within the test area.4 KB (637 words) - 21:00, 7 February 2023
- ...ovided in [https://www.astm.org/Standards/D7503.htm ASTM D7503-10 Standard Test Method for Measuring the Exchange Complex and Cation Exchange Capacity of I4 KB (584 words) - 01:22, 8 March 2018
- *Standard Test Method for Maximum Media Density for Dead Load Analysis of Vegetative (Gree *Test Method for Saturated Water Permeability of Granular Drainage Media [https:/3 KB (427 words) - 16:51, 1 May 2023
- !Recommended test method ...2% clay-sized particles (0.002 mm or smaller)||ASTM D6913/D6913M, Standard Test Methods for Particle-Size Distribution (Gradation) of Soils Using Sieve Ana9 KB (1,229 words) - 19:51, 21 November 2022
- ...er the top to prevent migration of the filter media into the pipe. The lab test states that the medium has a hydraulic conductivity of 25 mm/hr. The maximu ...top of the internal water storage reservoir clear stone aggregate. The lab test for the filter medium state that it has a hydraulic conductivity of 80 mm/h3 KB (540 words) - 18:58, 15 June 2022
- ...soil testing laboratory for soil organic matter analysis. The recommended test method depends on the organic matter content of the soil sample: ...and Nathan,M.V. 2012. “Soil Organic Matter.” In Recommended Chemical Soil Test Procedures for the North Central Region. North Central Regional Research Pu6 KB (933 words) - 17:57, 6 October 2022
- ...ided in [https://www.astm.org/Standards/D4972.htm ASTM D4972 - 13 Standard Test Method for pH of Soils]. When media test results fall outside of the specification range or acceptance criteria rang4 KB (634 words) - 20:45, 8 March 2018
- ...n is provided and the medium is free of fines and crushed stone. See [[Jar test]] to ensure there are no fines in the crushed stone aggregate.2 KB (341 words) - 17:18, 14 October 2022