{|{| class="wikitable"
+
|+Design parameters for dry ponds <ref>https://www.ontario.ca/document/stormwater-management-planning-and-design-manual/stormwater-management-plan-and-swmp-design</ref>
+
!Element
+
!Design Objective
+
!Criteria
+
|-
+
|Drainage Area
+
|Minimum orifice size (see [[flow control]])
+
|style="text-align: left|5 Ha (≥10 Ha preferred)
+
|-
+
|Treatment Volume
+
|Provision of appropriate level of protection
+
|style="text-align: left|See [[#.|below]]
+
|-
+
|Active Storage
+
|Detention
+
|style="text-align: left|[[Total Suspended solids|Suspended solids]] settling 24 hrs (48 hrs preferred)
+
|-
+
|Forebay
+
|Pre-treatment
+
|style="text-align: left|
+
*Minimum depth: 1 m;
+
*Sized to ensure non-erosive velocities leaving forebay;
+
|-
+
|Length-to-Width Ratio
+
|Maximize flow path and minimize short-circuiting potential
+
|style="text-align: left|
+
*Overall: minimum 3:1;
+
*4:1 preferred
+
|-
+
|Depth
+
|Safety
+
|style="text-align: left|Maximum 3 m
+
|-
+
|Side slopes (See also [[berms]])
+
|Safety
+
|style="text-align: left|
+
*4:1 average
+
|-
+
|Inlet
+
|Avoid clogging/freezing
+
|style="text-align: left|
+
*Minimum 450 mm;
+
*Preferred pipe slope: > 1 %;
+
*If submerged, obvert 150 mm below expected maximum ice depth
+
|-
+
|Outlet (See also [[flow control]])
+
|Avoid clogging/freezing
+
|style="text-align: left|
+
*Minimum: 450 mm outlet pipe;
+
*Preferred pipe slope: > 1 %;
+
*If orifice control used, 75 mm diameter minimum;
+
*Minimum 100 mm orifice preferable
+
|-
+
|Maintenance access
+
|Access for backhoes or dredging equipment
+
|style="text-align: left|
+
*Provided to approval of Municipality;
+
*Provision of maintenance drawdown pipe preferred
+
|-
+
|Buffer
+
|Safety
+
|style="text-align: left|Minimum 3 m above maximum water quality/erosion control water level
+
|}
+
+
+
+
+
+
+
+
+
+
+
The bottom of a dry pond should be flat to encourage uniform ponding and infiltration across the entire surface. Recommended tolerance on base levels 10 mm in 3m.