<math>d_{s, max}=\frac{f'\times t}{0.4}</math>
 
<math>d_{s, max}=\frac{f'\times t}{0.4}</math>
 
{{Plainlist|1=Where:
 
{{Plainlist|1=Where:
*''f''' = Design infiltration rate (mm/hr), and
+
*''f''' = [[Design infiltration rate]] (mm/hr), and
 
*''t'' = [[Drainage time]] (hrs), e.g. 96 hours, check local regulations for drainage time requirements.   
 
*''t'' = [[Drainage time]] (hrs), e.g. 96 hours, check local regulations for drainage time requirements.   
*''0.4'' = Void ratio of [[reservoir gravel|clear stone]]}}
+
*''0.4'' = Void ratio of [[Reservoir aggregate|clear stone]]}}
  
 
----
 
----

Revision as of 18:04, 26 September 2018

The following calculation is used to size the stone storage bed (reservoir) used as a base course. It is assumed that the footprint of the stone bed will be equal to the footprint of the pavement. The following equations are taken from the ICPI Manual [1]

To calculate the total depth of the stone reservoir (all graded layers)[edit]

The equation for the depth of the stone bed is as follows:

Where:

  • d = Stone bed depth (m)
  • Qc = Depth of runoff from contributing drainage area, not including permeable paving surface (m)
  • R = Ac/Ap; the ratio of contributing drainage area (Ac) to permeable paving area (Ap). Note that the contributing drainage area (Ac) should not contain pervious areas.
  • P = Rainfall depth (m)
  • f' = Design infiltration rate (m/day)
  • t = Time to fill stone bed (typically 2 hr)
  • VR = Void ratio for stone bed (typically 0.4 for 50 mm dia. clear stone)

To calculate the invert of the underdrain from the base of the reservoir[edit]

For designs that include an underdrain, the maximum depth of the stone reservoir below the invert of the underdrain pipe (ds, max) can be calculated as follows:

Where:


(f') used in the above equations should be the design infiltration rate that incorporates a safety correction factor. On highly permeable soils (e.g., infiltration rate of 45 mm/hr or greater), a maximum stone reservoir depth of 2 metres is recommended to prevent soil compaction and loss of permeability from the mass of overlying stone and stored water.