Line 17: | Line 17: | ||
* Geotechnical report; | * Geotechnical report; | ||
* Hydrogeological report; | * Hydrogeological report; | ||
+ | ==Figures and drawings== | ||
+ | * Location plan in the report; | ||
+ | * Key Plan on the drawings; | ||
+ | * All watercourses and names of watercourses shown on all figures and drawings; | ||
+ | * Pre-development and post-development drainage plans for hydrologic model(s) which include: | ||
+ | **Existing contours; | ||
+ | **Drainage direction (minor and major system); | ||
+ | **Catchments ID's; | ||
+ | **Areas and imperviousness; | ||
+ | **Uncontrolled areas; | ||
+ | **100 year capture; | ||
+ | **Site outlets; and | ||
+ | **SWM facility location and associated tributary areas; | ||
+ | * Model schematics; | ||
+ | * Storm drainage, grading and general servicing plans; | ||
+ | * SWM facility design drawings and details; | ||
+ | * Erosion and sediment control plans; | ||
− | + | ===Floodplain mapping and documentation minimum requirements=== | |
− | ===Floodplain mapping and documentation minimum requirements== | ||
# Hydraulic sections with regulated floodplain elevations and cross-section identification; | # Hydraulic sections with regulated floodplain elevations and cross-section identification; | ||
# Existing and proposed floodplain delineation; | # Existing and proposed floodplain delineation; |
Revision as of 01:31, 10 January 2018
Site Description[edit]
- Location (key plan, municipal address, nearest roads, watershed and subwatershed);
- Existing Conditions (land use on site and surrounding areas);
- Natural Heritage features;
- Proposed Conditions;
- Drainage Area (for the site, tributary and watershed);
- Watercourses, wetlands present on site, and type (permanent or intermittent);
- Drainage patterns and ultimate drainage location/outfall;
Background Information[edit]
- Pre-submission meeting verification;
- Reports from pre-consultation with MOECC and other agencies (especially related LID credits);
- Watershed plans;
- Sub-Watershed plans;
- Master drainage plans (MDPs);
- Other previous reports and relevant SWM requirements;
- Existing models;
- Geotechnical report;
- Hydrogeological report;
Figures and drawings[edit]
- Location plan in the report;
- Key Plan on the drawings;
- All watercourses and names of watercourses shown on all figures and drawings;
- Pre-development and post-development drainage plans for hydrologic model(s) which include:
- Existing contours;
- Drainage direction (minor and major system);
- Catchments ID's;
- Areas and imperviousness;
- Uncontrolled areas;
- 100 year capture;
- Site outlets; and
- SWM facility location and associated tributary areas;
- Model schematics;
- Storm drainage, grading and general servicing plans;
- SWM facility design drawings and details;
- Erosion and sediment control plans;
Floodplain mapping and documentation minimum requirements[edit]
- Hydraulic sections with regulated floodplain elevations and cross-section identification;
- Existing and proposed floodplain delineation;
- Topographic information including elevations and contours;
- Conveyance structures including dams, bridges, culverts and weirs;
- Man-made structures as applicable including buildings, roads, railways and trails;
- Natural reservoirs or natural storage areas;
- Spills analysis as applicable;
- Cut/fill analysis in the regulated area as applicable;
- Natural features such as watercourses and wetlands;
- Floodplain mapping and supporting documentation signed and stamped by a P.Eng.
Survey Documentation Minimum Requirements[edit]
For any submission which contains drawings or figures that present survey information, the following list of minimum requirements must be included:
- Document with text descriptor identifying overall approach and methodology;
- Drawing/Figure Title;
- Date, and Revision List where applicable;
- Legible Scale and North direction arrow;
- OLS Surveyor Name and contact information, as applicable;
- Geodetic benchmark data used in survey, as applicable;
- Available survey data for topographic surface, structures, features, etc.;
- Structures invert, obvert elevations and dimensions as applicable;
- Bathymetry as applicable;
- Documentation to support reported data accuracy;
- Methodology for survey data collected i.e. Total Station, GIS, Rod and Level;
- Photo log of structures survey including upstream, downstream and structures completed with structure survey;
- Drawings and / or figures to be submitted both electronically and in hard copy as requested;
- Digital copy of the survey data when applicable; and
- Submission components to be stamped and signed by an OLS, P.Eng. or C.E.T. as relevant.
Geospatial Data Submission Minimum Requirements[edit]
For a submission which contain drawings, figures, reports, modelling and / or memos that present geospatial information and its analysis; the following list of minimum requirements must be included:
- Text summary identifying methodology and software used in geospatial analysis;
- Acquisition type i.e. LIDAR, orthophotos, etc.;
- Date of data acquisition;
- Name of supplier of digital information and their contact information;
- Quality Assurance / Quality Control methodology for geo-spatial as applicable;
- Data Co-ordinate system;
- Data Projection;
- Data Horizontal and vertical resolution;
- Data Accuracy for each axis as applicable;
- Description of grid resolution;
- Drawing and / or figure scale identified as applicable;
- Contours presented at minimum 0.5 m increments;
- Orthophoto Elevation Data i.e. study area break lines and DTM points;
- LIDAR Elevation Data i.e. study area point cloud (as applicable);
- Digital Elevation Model (DEM) as applicable;
- Description of modifications to surface including adjustments to the TIN from other sources (i.e. surveyed culverts, new infrastructure invert and obvert elevations etc.);
- Flood limit data;
- Drawings and / or figures to be submitted both electronically and in hard copy when requested;
- In modelling files and documentation to maintain existing watercourse naming conventions were applicable;
- Projected Co-ordinate system: Preferably NAD 1983 UTM Zone 17N;
- Accepted Original Geospatial Data file format: File Geodatabase or Shapefiles; and
- Submission components to be stamped and signed by an OLS, P.Eng. or C.E.T. as relevant.