Line 6: | Line 6: | ||
* The minimum level spreader length is 4 m and the maximum is 40 m. | * The minimum level spreader length is 4 m and the maximum is 40 m. | ||
* The level spreader lip should be concrete, wood or pre-fabricated metal, with a well anchored footer, or other accepted rigid, non-erodible material. | * The level spreader lip should be concrete, wood or pre-fabricated metal, with a well anchored footer, or other accepted rigid, non-erodible material. | ||
− | * The ends of the level spreader section should be tied back into the slope to avoid scouring around the ends of the | + | * The ends of the level spreader section should be tied back into the slope to avoid [[overflow]] scouring or erosion around the ends of the spreader. |
* The width of the level spreader channel on the up-stream side of the level lip should be three times the diameter of the inflow pipe, and the depth should be 20 cm or one-half the culvert diameter, whichever is greater. | * The width of the level spreader channel on the up-stream side of the level lip should be three times the diameter of the inflow pipe, and the depth should be 20 cm or one-half the culvert diameter, whichever is greater. | ||
---- | ---- |
Revision as of 02:13, 6 November 2017
Level spreaders should conform to the following design criteria in order to ensure non-erosive sheet flow into vegetated areas such as vegetated filter strips, swales or forested conservation areas[1].
The length of the level spreader should be determined by the type of filter area and the design flow:
- 1.4 m of level spreader length per every 0.01 cubic meter per second (cms) of inflow for discharges to a filter strip or turf conservation area;
- 4.3 m of level spreader length per every 0.01 cms of inflow when the spreader discharges to a forested conservation area.
- The minimum level spreader length is 4 m and the maximum is 40 m.
- The level spreader lip should be concrete, wood or pre-fabricated metal, with a well anchored footer, or other accepted rigid, non-erodible material.
- The ends of the level spreader section should be tied back into the slope to avoid overflow scouring or erosion around the ends of the spreader.
- The width of the level spreader channel on the up-stream side of the level lip should be three times the diameter of the inflow pipe, and the depth should be 20 cm or one-half the culvert diameter, whichever is greater.
- ↑ Hathaway, J. M., & Hunt, W. F. (2006). Level Spreaders : Overview , Design , and Maintenance.