Changes

Jump to navigation Jump to search
Line 323: Line 323:  
*visible sediment accumulation in the bottom of the pond or around the high water line of the pond - may indicate need for sediment removal
 
*visible sediment accumulation in the bottom of the pond or around the high water line of the pond - may indicate need for sediment removal
   −
{| class="wikitable" style="text-align:center"
+
{| class="wikitable" style="float:right; margin-left:15px;
 
|+ Maximum allowable sediment accumulation (m³/ha) in dry ponds by catchment imperviousness for basic protection (STEP, 2016)<ref>STEP. 2016. Inspection and maintenance guide for stormwater management ponds and constructed wetlands. https://sustainabletechnologies.ca/app/uploads/2018/04/SWMFG2016_Guide_April-2018.pdf</ref>
 
|+ Maximum allowable sediment accumulation (m³/ha) in dry ponds by catchment imperviousness for basic protection (STEP, 2016)<ref>STEP. 2016. Inspection and maintenance guide for stormwater management ponds and constructed wetlands. https://sustainabletechnologies.ca/app/uploads/2018/04/SWMFG2016_Guide_April-2018.pdf</ref>
 
! Catchment Imperviousness !! Sediment Accumulation (m³/ha)
 
! Catchment Imperviousness !! Sediment Accumulation (m³/ha)
Line 335: Line 335:  
| 85% || 133
 
| 85% || 133
 
|}
 
|}
 +
 +
A field data sheet for the inspection of constructed wetlands is available below. You can download (downward facing arrow on the top righthand side) and print (Printer emoticon on top right hand side) the Dry Pond or Dry Extended Detention Basin Inspection and Maintenance Checklist developed by the City of Ontario, Ohio<ref>City of Ontario, Ohio. https://ontarioohio.org/stormwater-management/</ref>.
 +
 +
<pdf width="450" height="600">File:Post-Construction-OM-Dry-Basin-Inspection-Sheet.pdf</pdf>
 +
 
<br clear="all" />
 
<br clear="all" />
  