|Thickness will range from 50 mm - 100 mm depending on the expected loads.
 
|Thickness will range from 50 mm - 100 mm depending on the expected loads.
 
|-
 
|-
|'''Permeable Interlocking Pacements'''
+
|'''Permeable Interlocking Pavements'''
 
|
 
|
 
*Pavers shall meet the minimum material and standard specifications for precast concrete pavers (CSA A231.2 in Canada; ASTM C936 in United States).  
 
*Pavers shall meet the minimum material and standard specifications for precast concrete pavers (CSA A231.2 in Canada; ASTM C936 in United States).  

Revision as of 18:06, 5 August 2020

Specifications for pervious concrete, porous asphalt, and permeable pavers
Material Specification Quantity
Pervious concrete
  • NO4-RG-S7 mix with air entrainment proven to have the best freeze-thaw durability after 300 freeze-thaw cycles.
  • 28 day compressive strength = 5.5 to 20 MPa.
  • Porosity between 14% to 31%.
  • Permeability = 900 to 21,500 mm/hr.
  • Proprietary pre-cast slabs meeting required specifications are also available.
Thickness will range from 100 mm - 150 mm depending on the expected loads.
Porous asphalt
  • Open-graded asphalt mix with a minimum porosity of 16%.
  • Polymers can be added to provide additional strength to heavy loads.
  • The University of New Hampshire Stormwater Center has detailed design specifications for porous asphalt.
Thickness will range from 50 mm - 100 mm depending on the expected loads.
Permeable Interlocking Pavements
  • Pavers shall meet the minimum material and standard specifications for precast concrete pavers (CSA A231.2 in Canada; ASTM C936 in United States).
  • Open space between pavers (i.e. joint space) typically ranges between 5 and 15% of the total surface area.
  • ASTM No. 8 (5 mm dia.) crushed aggregate is recommended for fill material in the paver joints (typically HPB).
  • For narrow joint pavers, a smaller sized aggregate may be used. Narrow joints are required where pavement must be AODA compliant.
  • For vehicle applications the minimum paver thickness is 80 mm
  • For pedestrian applications the minimum paver thickness is 60 mm and joint widths should be no greater than 15 mm.