*The granular base material shall be crushed stone conforming to ASTM C 33 No 57. Material should be clear crushed 20 mm diameter stone. | *The granular base material shall be crushed stone conforming to ASTM C 33 No 57. Material should be clear crushed 20 mm diameter stone. | ||
*The granular bedding material shall be graded in accordance with ASTM C 33 No 8. Typical bedding thickness is 40 to 75 mm. Material should be 5 mm diameter stone or as determined by the Design Engineer. In Ontario, high performance bedding (1 to 9 mm diameter) or equivalent is often used. | *The granular bedding material shall be graded in accordance with ASTM C 33 No 8. Typical bedding thickness is 40 to 75 mm. Material should be 5 mm diameter stone or as determined by the Design Engineer. In Ontario, high performance bedding (1 to 9 mm diameter) or equivalent is often used. | ||
− | *See LID Planning and Design Wiki ([[Permeable | + | *See LID Planning and Design Wiki ([[Permeable pavements: Sizing]]) to size aggregate bed depth and multiply by application area to get total volume. |
|- | |- | ||
|'''Geotextile''' | |'''Geotextile''' |
Latest revision as of 19:53, 3 November 2022
Material | Specification | Quantity |
---|---|---|
Pervious concrete |
|
Thickness will range from 100 mm - 150 mm depending on the expected loads. |
Porous asphalt |
|
Thickness will range from 50 mm - 100 mm depending on the expected loads. |
Permeable Interlocking Pavements |
|
|
Stone Resevoir |
100 revolutions and maximum of 50% for 500 revolutions
|
|
Geotextile |
|
|
Underdrain (optional) |
|
Pipes should terminate 0.3 m short from the sides of the base. |