Difference between revisions of "Notation"
Jump to navigation
Jump to search
Dean Young (talk | contribs) |
Dean Young (talk | contribs) |
||
Line 10: | Line 10: | ||
;d<sub>m</sub> :Filter media depth of a bioretention, stormwater planter or soil cell practice (unit of length, usually mm or cm) | ;d<sub>m</sub> :Filter media depth of a bioretention, stormwater planter or soil cell practice (unit of length, usually mm or cm) | ||
+ | |||
+ | ;d<sub>s</sub> :Storage reservoir depth of an infiltration practice (unit of length, usually mm or cm) | ||
;d<sub>T</sub> :Total depth of an infiltration practice (unit of length, usually cm or m) | ;d<sub>T</sub> :Total depth of an infiltration practice (unit of length, usually cm or m) | ||
Line 53: | Line 55: | ||
;SCF :Safety correction factor (dimensionless) | ;SCF :Safety correction factor (dimensionless) | ||
− | ;t :time (usually in hrs) | + | ;t :Drainage time (usually in hrs) |
;T :Temperature (°C) | ;T :Temperature (°C) |
Revision as of 17:50, 22 April 2020
- Ac
- Area of the catchment, whole contributing drainage area (usually in m2).
- Ai
- Area of impervious cover within the catchment (usually in m2).
- Ap
- Area of the practice e.g. footprint area of a bioretention cell (usually in m2)
- D
- Duration of the design storm event (in units of time, usually hrs)
- dp
- Surface ponding depth of an infiltration practice (unit of length, usually mm or cm)
- dm
- Filter media depth of a bioretention, stormwater planter or soil cell practice (unit of length, usually mm or cm)
- ds
- Storage reservoir depth of an infiltration practice (unit of length, usually mm or cm)
- dT
- Total depth of an infiltration practice (unit of length, usually cm or m)
- f
- Infiltration rate, measured (usually mm/hr)
- f'
- Design infiltration rate (length per time, usually mm/hr) after application of safety correction factor (SCF)
- h
- height (units of length)
- i
- Intensity of the design storm event (in units of depth/time, usually mm/hr)
- i
- Thornthwaite monthly heat index (-)
- I
- Thornthwaite annual heat index (-)
- L
- Length, e.g. of a reach, channel or swale (usually in m)
- m
- run of side slopes in channel cross sections (length, but usually expressed as a ratio in relation to rise. e.g. side slopes = 1:3, so m = 3)
- n
- Porosity, applies to aggregate and other void-forming materials, filter media and native soils (unit is vol/vol, so dimensionless)
- n
- Manning's coefficient (unitless) Note: the symbol n is also used for porosity so it is important to be sure which term is implied.
- N
- Number of days in the month
- Qp
- Peak flow in units of volume per time (e.g. m3/s)
- R
- Ratio of catchment (Ac) to the practice footprint area (Ap). syn. I/P ratio. For green roofs (and often permeable paving systems) this will be 1:1. In bioretention it may be 15 or 20 to 1.
- Ra
- Existing rise of swale gradient (length, usually m)
- Rb
- Rise of compensation gradient for an enhanced swale (length, usually m)
- RVCT
- Runoff volume control target (as outlined by MECP, units are mm)
- S0
- Longitudinal slope (m/m, i.e. dimensionless)
- ST
- Storage (m3)
- Sx
- Cross slope (m/m, i.e. dimensionless)
- SCF
- Safety correction factor (dimensionless)
- t
- Drainage time (usually in hrs)
- T
- Temperature (°C)
- V
- Volume (usually in m3)
- x
- Perimeter of infiltration practice or swale x-section (m)
- y
- Depth of water (L, usually m or sometimes mm)