Difference between revisions of "Safety correction factors"

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
m (Redirected page to Design infiltration rate)
 
(18 intermediate revisions by the same user not shown)
Line 1: Line 1:
{|class="wikitable"
+
#REDIRECT [[Design infiltration rate]]
|+ Safety correction factors for calculating design infiltration rates<ref>Wisconsin Department of Natural Resources. 2004. Conservation Practice Standards. Site Evaluation for Stormwater Infiltration (1002). Madison, WI.</ref>
 
|-
 
!Ratio of Mean Measured Infiltration Rates
 
!Safety Correction Factor
 
|-
 
|≤ 1
 
|2.5
 
|-
 
|1.1 to 4.0
 
|3.5
 
|-
 
|4.1 to 8.0
 
|4.5
 
|-
 
|8.1 to 16.0
 
|6.5
 
|-
 
|16.1 or greater
 
|8.5
 
|}
 
 
 
<math>q'=\frac{q}{SCF}</math>
 

Latest revision as of 18:17, 1 October 2018