Difference between revisions of "Permeable pavements: Specifications"

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
m (Jenny Hill moved page Specifications to Permeable paving: Specifications without leaving a redirect)
m
Line 6: Line 6:
 
!Quantity
 
!Quantity
 
|-
 
|-
|'''Pervious Concrete'''
+
|'''Pervious concrete'''
 
|
 
|
 
* 28 day compressive strength = 5.5 to 20 MPa   
 
* 28 day compressive strength = 5.5 to 20 MPa   
Line 13: Line 13:
 
|Thickness will range from 100 mm - 150 mm depending on the expected loads
 
|Thickness will range from 100 mm - 150 mm depending on the expected loads
 
|-
 
|-
|'''Porous Asphalt'''
+
|'''Porous asphalt'''
 
|
 
|
 
* open-graded asphalt mix with a minimum of 16 % air voids  
 
* open-graded asphalt mix with a minimum of 16 % air voids  
Line 19: Line 19:
 
|Thickness will range from 50 mm - 100 mm depending on the expected loads
 
|Thickness will range from 50 mm - 100 mm depending on the expected loads
 
|-
 
|-
|'''Permeable Pavers'''
+
|'''Permeable pavers'''
 
|
 
|
*ASTM No. 8(5 mm dia) crused aggregate is recommended for fill material in the paver openings.
+
*ASTM No. 8(5 mm dia) crushed aggregate is recommended for fill material in the paver openings.
*Pavers shall meet the minimum material and standard specification for Precast Concrete Pavers.
+
*Pavers shall meet the minimum material and standard specification for precast concrete pavers.
 
*Pigment in concrete pavers shall conform to ASTM C 979 ACI Report No. 212.3R provides guidance on the use of pigments.
 
*Pigment in concrete pavers shall conform to ASTM C 979 ACI Report No. 212.3R provides guidance on the use of pigments.
 
*Maximum allowable breakage of product is 5%
 
*Maximum allowable breakage of product is 5%
 
|
 
|
 
*For vehicle applications the minimum paver thickness is 80 mm
 
*For vehicle applications the minimum paver thickness is 80 mm
*For pedestrian applications is 60 mm and Joint widths should be no greater than 15 mm.  
+
*For pedestrian applications is 60 mm and joint widths should be no greater than 15 mm.  
 
|-
 
|-

Revision as of 19:37, 19 October 2018

Specifications for pervious concrete, porous asphalt, and permeable pavers
Material Specification Quantity
Pervious concrete
  • 28 day compressive strength = 5.5 to 20 MPa
  • Void ratio = 14% - 31%
  • Permeability = 900 - 21,500 mm/hr
Thickness will range from 100 mm - 150 mm depending on the expected loads
Porous asphalt
  • open-graded asphalt mix with a minimum of 16 % air voids
  • Polymer can be added to provide additional strength to heavy loads
Thickness will range from 50 mm - 100 mm depending on the expected loads
Permeable pavers
  • ASTM No. 8(5 mm dia) crushed aggregate is recommended for fill material in the paver openings.
  • Pavers shall meet the minimum material and standard specification for precast concrete pavers.
  • Pigment in concrete pavers shall conform to ASTM C 979 ACI Report No. 212.3R provides guidance on the use of pigments.
  • Maximum allowable breakage of product is 5%
  • For vehicle applications the minimum paver thickness is 80 mm