Difference between revisions of "Notation"

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
m
(8 intermediate revisions by the same user not shown)
Line 1: Line 1:
;A<sub>c</sub>
+
;A<sub>c</sub> :Area of the catchment, whole contributing drainage area (usually in m<sup>2</sup>).  
:Area of the catchment, whole contributing drainage area (usually in m<sup>2</sup>).  
 
  
;A<sub>p</sub>
+
;A<sub>p</sub> :Area of the practice e.g. footprint area of a bioretention cell (usually in m<sup>2</sup>)
:Area of the practice e.g. footprint area of a bioretention cell (usually in m<sup>2</sup>)
 
  
;d
+
;d :Depth e.g. of an infiltration practice (units of length, usually mm or m)
:Depth e.g. of an infiltration practice (units of length, usually m)
 
  
;L
+
;f :Infiltration rate (usually mm/hr)
:Length, e.g. of a reach, channel or swale (usually in m)
 
  
;m
+
;h :height (units of length)
:run of side slopes in channel cross sections (length, but usually expressed as a ratio in relation to rise. e.g. side slopes = 1:3, so m = 3)
 
  
;n
+
;i :Thornthwaite monthly heat index (-)
:Manning's coefficient (unitless) Note: for clarity porosity is being expressed as 'void ratio' and sharing the notation V<sub>R</sub>
 
  
;P
+
;I :Thornthwaite annual heat index (-)
:Perimeter of infiltration practice or swale x-section (m)
 
  
;q
+
;L :Length, e.g. of a reach, channel or swale (usually in m)
:Infiltration rate in (length per time, usually mm/hr)
 
  
;q'
+
;m :run of side slopes in channel cross sections (length, but usually expressed as a ratio in relation to rise. e.g. side slopes = 1:3, so m = 3)
:Infiltration coefficient in (length per time, usually mm/hr) after application of safety correction factor (SCF)
 
  
;Q<sub>p</sub>
+
;n :Manning's coefficient (unitless) Note: for clarity porosity is being expressed as 'void ratio' and sharing the notation V<sub>R</sub>
:Peak flow in units of volume per time (e.g. m<sup>3</sup>/s)
 
  
;R
+
;N :Number of days in the month
:Ratio of catchment (A<sub>c</sub>) to the practice footprint area (A<sub>p</sub>). ''syn.'' I/P ratio. For [[green roofs]] (and often permeable paving systems) this will be 1:1. In [[bioretention]] it may be 15 or 20 to 1. 
 
  
;R<sub>a</sub>
+
;P :Perimeter of infiltration practice or swale x-section (m)
:Existing rise of swale gradient (length, usually m)
 
  
;R<sub>b</sub>
+
;q :Infiltration rate in (length per time, usually mm/hr)
:Rise of compensation gradient for an enhanced swale (length, usually m)
 
  
;RVC<sub>T</sub>
+
;q':Infiltration coefficient in (length per time, usually mm/hr) after application of safety correction factor (SCF)
:Runoff volume control target (as outlined by MOECC, units are mm)
 
  
;S<sub>0</sub>
+
;Q<sub>p</sub> :Peak flow in units of volume per time (e.g. m<sup>3</sup>/s)
:Longitudinal slope (m/m, i.e. dimensionless)
 
  
;S<sub>x</sub>
+
;R :Ratio of catchment (A<sub>c</sub>) to the practice footprint area (A<sub>p</sub>). ''syn.'' I/P ratio. For [[green roofs]] (and often permeable paving systems) this will be 1:1. In [[bioretention]] it may be 15 or 20 to 1. 
:Cross slope (m/m, i.e. dimensionless)
 
  
;SCF
+
;R<sub>a</sub> :Existing rise of swale gradient (length, usually m)
:Safety correction factor (dimensionless)
 
  
;t
+
;R<sub>b</sub> :Rise of compensation gradient for an enhanced swale (length, usually m)
:time (usually in hrs)
 
  
;V<sub>R</sub>
+
;RVC<sub>T</sub> :Runoff volume control target (as outlined by MOECC, units are mm)
:Void ratio, as usually applied to aggregates and yard materials. In this guide, it is also applied to native soils in lieu of porosity (unit for both are vol/vol, i.e. dimensionless)
 
  
;y
+
;S<sub>0</sub> :Longitudinal slope (m/m, i.e. dimensionless)
:Depth of water (length, usually m or sometimes mm)
+
 
 +
;S<sub>T</sub> :Storage (m<sup>3</sup>)
 +
 
 +
;S<sub>x</sub> :Cross slope (m/m, i.e. dimensionless)
 +
 
 +
;SCF :Safety correction factor (dimensionless)
 +
 
 +
;t :time (usually in hrs)
 +
 
 +
;T :Temperature (°C)
 +
 
 +
;V :Volume (usually in m<sup>3</sup>)
 +
 
 +
;V<sub>R</sub> :Void ratio, as usually applied to aggregates and yard materials. In this guide, it is also applied to native soils in lieu of porosity (unit for both are vol/vol, i.e. dimensionless)
 +
 
 +
;y :Depth of water (L, usually m or sometimes mm)

Revision as of 18:06, 26 September 2018

Ac
Area of the catchment, whole contributing drainage area (usually in m2).
Ap
Area of the practice e.g. footprint area of a bioretention cell (usually in m2)
d
Depth e.g. of an infiltration practice (units of length, usually mm or m)
f
Infiltration rate (usually mm/hr)
h
height (units of length)
i
Thornthwaite monthly heat index (-)
I
Thornthwaite annual heat index (-)
L
Length, e.g. of a reach, channel or swale (usually in m)
m
run of side slopes in channel cross sections (length, but usually expressed as a ratio in relation to rise. e.g. side slopes = 1:3, so m = 3)
n
Manning's coefficient (unitless) Note: for clarity porosity is being expressed as 'void ratio' and sharing the notation VR
N
Number of days in the month
P
Perimeter of infiltration practice or swale x-section (m)
q
Infiltration rate in (length per time, usually mm/hr)
q'
Infiltration coefficient in (length per time, usually mm/hr) after application of safety correction factor (SCF)
Qp
Peak flow in units of volume per time (e.g. m3/s)
R
Ratio of catchment (Ac) to the practice footprint area (Ap). syn. I/P ratio. For green roofs (and often permeable paving systems) this will be 1:1. In bioretention it may be 15 or 20 to 1.
Ra
Existing rise of swale gradient (length, usually m)
Rb
Rise of compensation gradient for an enhanced swale (length, usually m)
RVCT
Runoff volume control target (as outlined by MOECC, units are mm)
S0
Longitudinal slope (m/m, i.e. dimensionless)
ST
Storage (m3)
Sx
Cross slope (m/m, i.e. dimensionless)
SCF
Safety correction factor (dimensionless)
t
time (usually in hrs)
T
Temperature (°C)
V
Volume (usually in m3)
VR
Void ratio, as usually applied to aggregates and yard materials. In this guide, it is also applied to native soils in lieu of porosity (unit for both are vol/vol, i.e. dimensionless)
y
Depth of water (L, usually m or sometimes mm)