Changes

Jump to navigation Jump to search
m
Line 10: Line 10:  
{{:Depth to GW}}
 
{{:Depth to GW}}
 
If there is a constraint to the depth (''d<sub>T</sub>'') of the bioretention practice calculate the require facility area or footprint where the depth is constrained, as:
 
If there is a constraint to the depth (''d<sub>T</sub>'') of the bioretention practice calculate the require facility area or footprint where the depth is constrained, as:
<math>A_{p}=\frac{A_c\times i\times D}{(V_{R}\times d_{T})+(f'\times)D}</math>
+
<math>A_{p}=\frac{A_c\times i\times D}{(V_{R}\times d_{T})+(f'\timesD)}</math>
 
{{Plainlist|1=Where:
 
{{Plainlist|1=Where:
 
*''A<sub>p</sub>'' = Area of the infiltration practice in m<sup>2</sup>
 
*''A<sub>p</sub>'' = Area of the infiltration practice in m<sup>2</sup>
Line 17: Line 17:  
*''i'' = Intensity of design storm in mm/hr
 
*''i'' = Intensity of design storm in mm/hr
 
*''f''' = [[design infiltration rate]] in mm/hr
 
*''f''' = [[design infiltration rate]] in mm/hr
*''V<sub>R</sub>'' = Void ratio (porosity), as measured (or default to 0.35 for all aggregates)
+
*''V<sub>R</sub>'' = Mean void ratio of the fill within the practice
*
   
*''d<sub>T</sub>'' = Total depth of the infiltration practice in m.}}
 
*''d<sub>T</sub>'' = Total depth of the infiltration practice in m.}}
  
8,255

edits

Navigation menu