Of the standard granular materials in the standard OPSS.MUNI 1010 only '''Granular O''' is recommended as a substitute for [[reservoir aggregate| clear stone]].  
+
<include only>Of the standard granular materials in the standard OPSS.MUNI 1010 only '''Granular O''' is recommended as a substitute for [[reservoir aggregate| clear stone]].  
 
{{Textbox|1= Where Granular O is substituted for clear stone in underground reservoir structures, the void ratio used in design calculations shall be '''0.3''' unless laboratory testing proves otherwise.}}
 
{{Textbox|1= Where Granular O is substituted for clear stone in underground reservoir structures, the void ratio used in design calculations shall be '''0.3''' unless laboratory testing proves otherwise.}}
 
Examples of BMPs with underground reservoirs include [[Underdrains]], [[infiltration trenches]], [[permeable paving]], [[infiltration chambers]], [[exfiltration trenches]].  
 
Examples of BMPs with underground reservoirs include [[Underdrains]], [[infiltration trenches]], [[permeable paving]], [[infiltration chambers]], [[exfiltration trenches]].  
    
All other mixes must be avoided for free drainage or storage as they are permitted to contain a higher enough proportion of fines to reduce permeability below 50 mm/hr.   
 
All other mixes must be avoided for free drainage or storage as they are permitted to contain a higher enough proportion of fines to reduce permeability below 50 mm/hr.   
 
+
</include only>
 
===Justification===
 
===Justification===
   Line 80: Line 80:  
Permeability (''K'') was estimated from the 10th percentile grain size using the [[Hazen]] formula.   
 