The maximum flow rate through a bed of filter media (''Q<sub>max, m</sub>'', L/s) may be calculated:
 
The maximum flow rate through a bed of filter media (''Q<sub>max, m</sub>'', L/s) may be calculated:
<math>Q_{max, m}=\frac{K_{m}\times A_{p}\times \left (\frac{\sum d}{d_{m}}  \right )}{3600}</math>
+
<math>Q_{max, m}=\frac{K_{m}\times A_{p}\times \left (\frac{\sum h}{d_{m}}  \right )}{3600}</math>
 
{{Plainlist|1=Where:
 
{{Plainlist|1=Where:
 
*''K<sub>m</sub>'' is the hydraulic conductivity of the filter media (mm/hr),  
 
*''K<sub>m</sub>'' is the hydraulic conductivity of the filter media (mm/hr),  
 
*''A<sub>p</sub>'' is the area of the practice (m<sup>2</sup>),  
 
*''A<sub>p</sub>'' is the area of the practice (m<sup>2</sup>),  
*''Σ d'' is the total depth of bioretention components over the perforated pipe (m) (e.g. ponding/[[mulch]]/[[filter media]]/[[choker layer]]), and
+
*''Σ h'' is the total depth of bioretention components over the perforated pipe (m) (e.g. ponding/[[mulch]]/[[filter media]]/[[choker layer]]), and
 
*''d<sub>m</sub>'' is the depth of the filter media (m).  
 
*''d<sub>m</sub>'' is the depth of the filter media (m).  
 
}}
 
}}