Difference between revisions of "Filter strips: TTT"

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
m
m
Line 7: Line 7:
 
|width = 210px|Berm height (mm)||This is the height of the curb which constrains the overland sheet flow of water. Where the bottom of the slope discharges directly into another LID facility without impedance, the value is 0.   
 
|width = 210px|Berm height (mm)||This is the height of the curb which constrains the overland sheet flow of water. Where the bottom of the slope discharges directly into another LID facility without impedance, the value is 0.   
 
|-
 
|-
|Surface roughness (Manning’s n)||Lower numbers indicate less surface obstruction and result in faster flow. Suggested range for mown grass (dependent on density) 0.03 – 0.06 <ref name = SWMM> Oregon State Univ., Corvallis. Dept. of Civil, Construction and Environmental Engineering.; Environmental Protection Agency, Cincinnati ONRMRL. Storm Water Management Model Reference Manual Volume I Hydrology (Revised). 2016:233. https://nepis.epa.gov/Exe/ZyPURL.cgi?Dockey=P100NYRA.txt Accessed August 23, 2017.</ref>
+
|Surface roughness (Manning’s n)||Lower numbers indicate less surface obstruction and result in faster flow. See [[Turf]]
 
|-
 
|-
 
|Surface slope (%)||If the slope > 3%, consider using [[level spreaders]] to reduce erosion of the surface under high flow velocities.  
 
|Surface slope (%)||If the slope > 3%, consider using [[level spreaders]] to reduce erosion of the surface under high flow velocities.  

Revision as of 15:11, 6 March 2018

TTT.png

Vegetated filter strips are found within the LID toolbox
Surface
Berm height (mm) This is the height of the curb which constrains the overland sheet flow of water. Where the bottom of the slope discharges directly into another LID facility without impedance, the value is 0.
Surface roughness (Manning’s n) Lower numbers indicate less surface obstruction and result in faster flow. See Turf
Surface slope (%) If the slope > 3%, consider using level spreaders to reduce erosion of the surface under high flow velocities.
Soil (native underlying soil, or amended topsoil)
Thickness (mm) If topsoil has been amended Absorbent landscapes
Porosity (fraction) Suggest range 0.35 – 0.4, unless otherwise tested
Field capacity (fraction) Will vary according to native or amended topsoil[1]
Wilting point (fraction)
Conductivity (mm/hr)
Conductivity slope
Suction head (mm)
Design drawdown time (hrs) ?
  1. Cite error: Invalid <ref> tag; no text was provided for refs named SWMM