For advice on decorative surface aggregates see '''[[Stone]]'''
+
Did you want an article on [[Reservoir gravel]] or [[choking layer|finer gravel]]?
 
 
*Granular material for underdrains should be clear crushed 20 or 50 mm diameter stone graded in accordance with [https://www.astm.org/Standards/D2940.htm ASTM D 2940],
 
*The 20 mm clear crushed aggregate permits the use of an overlaid layer of high performance bedding (HPB) as a choker layer,
 
*The void space ratio should be > 0.35 (or > 35%)
 
 
 
All gravel should meet the following criteria:
 
*Maximum wash loss of 0.5%
 
*Minimum durability index of 35
 
*Maximum abrasion of 10% for 100 revolutions and maximum of 50% for 500 revolutions
 
 
 