Changes

Jump to navigation Jump to search
m
Line 51: Line 51:  
The drainage of the bowl is not usually constrained by the surface infiltration (filter media should drain > 25 mm/hr). The infiltration of water from the bowl is determined by the drainage of the filter media and reservoir into the soils.   
 
The drainage of the bowl is not usually constrained by the surface infiltration (filter media should drain > 25 mm/hr). The infiltration of water from the bowl is determined by the drainage of the filter media and reservoir into the soils.   
 
To estimate the time (''t'') to fully drain the facility:  
 
To estimate the time (''t'') to fully drain the facility:  
:<math>t=\frac{V_{R}A_{p}} {q'P}ln\left [ \frac{\left (d+ \frac{A_{p}}{P} \right )}{\left(\frac{A_{p}}{P}\right)}\right]</math>
+
:<math>t=\frac{V_{R}A_{p}} {f'P}ln\left [ \frac{\left (d+ \frac{A_{p}}{P} \right )}{\left(\frac{A_{p}}{P}\right)}\right]</math>
 
</poem>
 
</poem>
  
8,255