Difference between revisions of "Talk:Soakaways, Infiltration Trenches and Infiltration Chambers Guide"

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
Line 5: Line 5:
 
!colspan="5" style="background: brown; color: white"|United States  
 
!colspan="5" style="background: brown; color: white"|United States  
 
|-
 
|-
!colspan="2" style="backgroung=green; color:white"|Soakaways, Infiltration Trenches and Chambers|| CVC+TRCA (Factsheets-2010)<ref> http://www.creditvalleyca.ca/wp-content/uploads/2012/02/lid-swm-guide-apdxa-bioretention.pdf</ref>|| Toronto- 2016 || LID-SWM Guide 2010<ref> http://www.creditvalleyca.ca/wp-content/uploads/2014/04/LID-SWM-Guide-v1.0_2010_1_no-appendices.pdf</ref>|| Massachusets SW BMP-2013 || District of Columbia-SWM Guidebook-2010 || W. Virginia-SWM design guidance manual-2012 || Pennsylvania-City of Philadelphia green St. design manual-2014 || Oregon SWM Manual-2014
+
!colspan="2" style="backgroung=green; color:white"|Soakaways, Infiltration Trenches and Chambers|| CVC+TRCA (Factsheets-2010)<ref> http://www.creditvalleyca.ca/wp-content/uploads/2012/02/lid-swm-guide-apdxa-soakaways-infiltration-trenches-chambers.pdf</ref>|| Toronto- 2016 || LID-SWM Guide 2010<ref> http://www.creditvalleyca.ca/wp-content/uploads/2014/04/LID-SWM-Guide-v1.0_2010_1_no-appendices.pdf</ref>|| Massachusets SW BMP-2013 || District of Columbia-SWM Guidebook-2010 || W. Virginia-SWM design guidance manual-2012 || Pennsylvania-City of Philadelphia green St. design manual-2014 || Oregon SWM Manual-2014
  
 
|-
 
|-
 
|colspan="2" |'''Setback from building Foundation(m)'''
 
|colspan="2" |'''Setback from building Foundation(m)'''
| 4 ||  || 4 ||  ||  ||  || ||
+
| 4 ||  || 4 ||  ||  ||  ||   ||
 
|-
 
|-
 
|colspan="2"|'''(Impervious drainage/treatment) area'''
 
|colspan="2"|'''(Impervious drainage/treatment) area'''
|5:1-20:1, 10:1 recommended ||  || 5:1-20:1, 10:1 recommended ||CDA < 5 acres||CDA < 2 acres (T), < 5 acres (B)||< 2 acres || Max. load of 10:1 for infiltration systems (not specific to LID type)||CDA: max. 15000 ft2||
+
|5:1-20:1, 10:1 recommended ||  || 5:1-20:1, 10:1 recommended ||CDA < 5 acres||CDA < 2 acres (T), < 5 acres (B)||< 2 acres || Max. load of 10:1 for infiltration systems (not specific to LID type)||CDA: max. 15000 ft2|
 
|-
 
|-
 
|colspan="2"|  '''Natural Slope (%)''' || < 15 ||  || < 15 ||  ||  ||  ||  ||  
 
|colspan="2"|  '''Natural Slope (%)''' || < 15 ||  || < 15 ||  ||  ||  ||  ||  

Revision as of 19:32, 3 October 2017

LID Practice CANADA United States
Soakaways, Infiltration Trenches and Chambers CVC+TRCA (Factsheets-2010)[1] Toronto- 2016 LID-SWM Guide 2010[2] Massachusets SW BMP-2013 District of Columbia-SWM Guidebook-2010 W. Virginia-SWM design guidance manual-2012 Pennsylvania-City of Philadelphia green St. design manual-2014 Oregon SWM Manual-2014
Setback from building Foundation(m) 4 4
(Impervious drainage/treatment) area 5:1-20:1, 10:1 recommended 5:1-20:1, 10:1 recommended CDA < 5 acres CDA < 2 acres (T), < 5 acres (B) < 2 acres Max. load of 10:1 for infiltration systems (not specific to LID type)
Natural Slope (%) < 15 < 15
A capped vertical sandpipe, perfored instaled to the bottom of the facility to monitor drainage time 100-150 mm 100-150 mm
Filter Mdia
Stone Resvoir 1.5" to 3" stone dia., 2" pea gravel above 6" sand below 1.5"-3.5" stone dia. For stone layer, 3" layer of washed river stone, or No. 8 or 89 stone above, 6-8 " of sand below Stone 1.5"-3.5" Drain rock 3/4"-2.5 " washed open graded aggregate
Void space(%) 30-40 30-40 30-40
Granular material (clear stone)(mm) 50 50 50
Geotextile around the stone reservoirwith an overlap at the top min. 300 mm 300 min. 300 mm
Bottom widh of excavations (mm) 600-2400 600-2400 600-2400
Minimum depth of excavations under concrete laneway (mm) 3000
length of time for draining after storm event (>25mm) max. 72 hr max.72 hr, 48 recommended
Depth to high water table (m) 1 1
Sand layer depth (mm) 150-300
Subdrains Inlet pipes (mm) 100-200
Overflow ( if infiltration rate ) < 15 mm/hr
Facilties reciving road runoff are not located within time of travel wellhead protection areas, year 2 2