To completely capture linear flow travelling along a gutter perpendicular to a curb inlet, the inlet must be of width::
 
To completely capture linear flow travelling along a gutter perpendicular to a curb inlet, the inlet must be of width::
 
<math>W_T=0.817Q^{0.42}S_{0}^{0.3}\left (\frac{1}{nS_{x}}\right)^{0.6}</math>
 
<math>W_T=0.817Q^{0.42}S_{0}^{0.3}\left (\frac{1}{nS_{x}}\right)^{0.6}</math>
 +
 +
{{Plainlist|1=Where:
 +
*''W<sub>T</sub>'' is the width of the inlet in m,
 +
*''Q'' is the flow perpendicular to the inlet in m<sup>3</sup?/s
 +
*''S<sub>0</sub>'' is the longitudinal slope
 +
*''n'' is Manning's 'n' (between 0.012 and 0.016 for concrete, depending on surface treatment),
 +
*''S<sub>x</sub>'' is the cross slope}}
    