Difference between revisions of "Rainwater harvesting: Sizing and modeling"
Jenny Hill (talk | contribs) (→Rapid) |
Jenny Hill (talk | contribs) |
||
Line 50: | Line 50: | ||
<div class="col-md-8"> | <div class="col-md-8"> | ||
<p>The Sustainable Technologies Evaluation Program have produced a rainwater harvesting design and costing tool specific to Ontario. The tool is in a simple to use Excel format and is free to download.</p> | <p>The Sustainable Technologies Evaluation Program have produced a rainwater harvesting design and costing tool specific to Ontario. The tool is in a simple to use Excel format and is free to download.</p> | ||
− | |||
</div> | </div> | ||
<div class="col-md-2"> | <div class="col-md-2"> |
Revision as of 19:24, 11 July 2017
Rapid[edit]
Five percent of the average annual yield can be estimated:
Y0.05= A × Cvol × Ra × e × 0.05
Y0.05 = Five percent of the average annual yield (L)
A = The catchment area ( m2)
Cvol = The runoff coefficient for the catchment
Ra = The average annual rainfall depth (mm)
e = The efficiency of the pre-storage filter
Five percent of the average annual demand (D0.05) can be estimated:
D0.05 = Pd × n × 18.25
D0.05 = Five percent of the average annual demand (L)
Pd = The daily demand per person (L)
n = The number of occupants
Good catchment selection means that the runoff coefficient (Cvol) should be 0.9 or greater. Filter efficiency (e) can be reasonably estimated as 0.9 pending manufacturer’s information.
Then the following calculations are based upon two criteria:
- A design rainfall depth is to be captured entirely by the RWH system.
- The average annual demand (D) is greater than the average annual yield (Y) from the catchment.
When Y0.05/ D0.05 < 0.33, the storage volume required (VS, in L) can be estimated:
VS = A × Cvol × Rd × e
VS = Storage volume required (L)
A = The catchment area (m2)
Cvol = The design storm runoff coefficient for the catchment
Rd = The design storm rainfall depth (mm), and
e = The efficiency of the pre-storage filter.
When 0.33 < Y0.05/ D0.05 < 0.7, the total storage required can be estimated by adding Y0.05:
Total storage = VS + Y0.05
<panelInfo>
</panelInfo>
STEP Rainwater Harvesting Tool[edit]
The Sustainable Technologies Evaluation Program have produced a rainwater harvesting design and costing tool specific to Ontario. The tool is in a simple to use Excel format and is free to download.
The Treatment Train Tool[edit]
Once the size of cistern has been determined, it can easily be modelled in many open source and proprietary applications.
In addition to the cistern size, this watershed scale modelling requires input information about draw down. time i.e. the rate of use.
<btnPrimary>The Treatment Train Tool</btnPrimary>
- REDIRECT Special:ArticleFeedbackv5