Changes

Jump to navigation Jump to search
Line 81: Line 81:     
===Underdrain===
 
===Underdrain===
Stormwater planters differ from full and/or partial infiltration [[bioretention]] practices in that the storage function is provided only by the [[Bioretention media storage|water retention capacity]] of the [[filter media]]. As such, there is no storage reservoir and the only purpose to the aggregate layer is to drain water to the perforated [[pipe]]. For this, a medium aggregate as described in [[choker layer]] is recommended as it negates the need for a separating layer to the filter media. Design details can be found here  [[Underdrains#Underdrains for non-exfiltrating practices|Underdrains]] for non-exfiltrationg practices.
+
Stormwater planters differ from full and/or partial infiltration [[bioretention]] practices in that the storage function is provided only by the [[Bioretention media storage|water retention capacity]] of the [[filter media]]. As such, there is no storage reservoir and the only purpose to the aggregate layer is to drain water to the perforated [[pipe]]. For this, a medium aggregate as described in [[choker layer]] is recommended as it negates the need for a separating layer to the filter media. Design details can be found here  [[Underdrains#Underdrains for non-exfiltrating practices|Underdrains]] for non-exfiltrating practices.
    
===Planting===
 
===Planting===
Line 149: Line 149:     
==Inspection and Maintenance==
 
==Inspection and Maintenance==
Stormwater planters requires regular, routine inspection and maintenance of the landscaping as well as periodic inspection of other parts of the facility, especially in heavily urbanized environments. Routine maintenance should include weeding, pruning, and mulching, similar to other landscaped areas, as well as the removal of trash, debris and sediment accumulated in pretreatment areas, inlets and outlets. Watering may be needed until plant establishment (first 2 years). <br>
+
Stormwater planters requires regular, routine inspection and maintenance of the landscaping as well as periodic inspection of other parts of the facility, especially in heavily urbanized environments. Routine maintenance should include weeding, pruning, and mulching, similar to other landscaped areas, as well as the removal of trash, debris and sediment accumulated in pretreatment areas, inlets and outlets. Watering may be needed until plant establishment (first 2 years). Periodic replacement of the top 5 cm of filter media around inlets (e.g., every 5 to 10 years) will help maintain treatment performance.<br>
 +
<br>
 
Inspections should occur twice annually (spring and late fall) and after major storm events. Inspect for vegetation density (≥ 80% coverage), damage by foot or vehicle traffic, erosion, debris, soil compaction and sediment accumulation, along with any damage to pretreatment devices.<br>
 
Inspections should occur twice annually (spring and late fall) and after major storm events. Inspect for vegetation density (≥ 80% coverage), damage by foot or vehicle traffic, erosion, debris, soil compaction and sediment accumulation, along with any damage to pretreatment devices.<br>
 
Cleanouts and access points should be provided to allow access to the underdrain and overflow pipe. Camera inspection of these pipes should be conducted every 5 years to ensure pipes are free of roots, sediment and debris. Hydraulic flushing or root removal may be needed to clear debris or obstructions.
 
Cleanouts and access points should be provided to allow access to the underdrain and overflow pipe. Camera inspection of these pipes should be conducted every 5 years to ensure pipes are free of roots, sediment and debris. Hydraulic flushing or root removal may be needed to clear debris or obstructions.