| | + | [[File:Double ring.jpg|thumb|Schematic diagram of double ring infiltrometer illustrating the infiltration of water both vertically, and laterally particularly from the outer ring.]] |
| | + | [[File:Bill's double ring.jpg|thumb|Double ring infiltrometer in use (Photo Source: Bill Trenouth, 2009)]] |
| | [[File:Double ring.JPG|thumb|Double ring]] | | [[File:Double ring.JPG|thumb|Double ring]] |
| − | [[File:Double ring.jpg|thumb|Schematic diagram of double ring infiltrometer illustrating the infiltration of water both vertically, and laterally particularly from the outer ring.]]
| + | {{TOClimit|2}} |
| − | [[File:Bill's double ring.jpg|thumb|Double ring infiltrometer in use]]
| |
| − | | |
| | ==Principle== | | ==Principle== |
| − | | + | Using a double ring infiltrometer is a relatively simple (although slow) method of measuring soil the hydraulic conductivity or ''[[design infiltration rate]]'' of a given [[Soil groups|soil]]. |
| | | | |
| | ==Measurements== | | ==Measurements== |
| Line 32: |
Line 33: |
| | | | |
| | ==Calculations== | | ==Calculations== |
| − | [[File:DRI.xlsx]] | + | Download a copy of our DRI (double ring infiltrometer) spreadsheet for this process. Directions are provided below. |
| | + | |
| | + | {{Clickable button|[[File:Double ring infilt.PNG|75px|link=https://wiki.sustainabletechnologies.ca/images/7/7f/DRI.xlsx]]}} |
| | + | |
| | + | {{#l:DRI.xlsx|Double ring to K}} |
| | | | |
| − | Using the DRI (double ring infiltrometer) spreadsheet:
| |
| | ===The Solver add-in=== | | ===The Solver add-in=== |
| | To use the calculation spreadsheet, an additional add-in must be enabled in your Excel program. | | To use the calculation spreadsheet, an additional add-in must be enabled in your Excel program. |
| Line 59: |
Line 63: |
| | ##The saturated hydraulic conductivity (K) is approximated by dividing A by 2/3, where A is the slope of the linear part of the graph. i.e when infiltration rate has stabilized. | | ##The saturated hydraulic conductivity (K) is approximated by dividing A by 2/3, where A is the slope of the linear part of the graph. i.e when infiltration rate has stabilized. |
| | | | |
| − | ==To review== | + | ==External references== |
| − | https://www.astm.org/Standards/D3385.htm | + | * See most recent version of ASTM D3385 for standard test method.<ref> ASTM International. 2018. ASTM D3385-18 Standard Test Method For Infiltration Rate of Soils in Field Using Double-Ring Infiltrometer.</ref> [https://www.astm.org/Standards/D3385.htm] |