Changes

Jump to navigation Jump to search
Line 25: Line 25:     
===[[Underdrain |Underdrains]] and flow control devices===
 
===[[Underdrain |Underdrains]] and flow control devices===
LID facilities have been demonstrated to function well throughout frozen periods of the year even when all components were fully frozen for some part of the year.  
+
LID facilities have been demonstrated to function well throughout frozen periods of the year even when all components were fully frozen for some part of the year.<br>
[[Underdrain]] perforated pipes should be located below the frost line to reduce the threat of ice clogging. Ontario provincial standard drawings of frost penetration depth are available from the [https://www.library.mto.gov.on.ca/SydneyPLUS/TechPubs/Portal/tp/opsViews.aspx Ministry of Transportation] as OPSD 3090.100 for northern Ontario <ref> Ministry of Transportation. 2010. Foundation Frost Penetration Depths for Northern Ontario. OPSD 3090.100. Nov 2010. Rev.1. https://www.library.mto.gov.on.ca/SydneyPLUS/TechPubs/Portal/tp/opsViews.aspx </ref> and OPSD 3090.101 for southern Ontario <ref> Ministry of Transportation. 2010. Foundation Frost Penetration Depths for Southern Ontario. OPSD 3090.101. Nov 2010. Rev.1. https://www.library.mto.gov.on.ca/SydneyPLUS/TechPubs/Portal/tp/opsViews.aspx </ref>.  
+
<br>
 +
[[Underdrain]] perforated pipes should be located below the frost line to reduce the threat of ice clogging. Ontario provincial standard drawings of frost penetration depth are available from the [https://www.library.mto.gov.on.ca/SydneyPLUS/TechPubs/Portal/tp/opsViews.aspx Ministry of Transportation] as OPSD 3090.100 for northern Ontario <ref> Ministry of Transportation. 2010. Foundation Frost Penetration Depths for Northern Ontario. OPSD 3090.100. Nov 2010. Rev.1. https://www.library.mto.gov.on.ca/SydneyPLUS/TechPubs/Portal/tp/opsViews.aspx </ref> and OPSD 3090.101 for southern Ontario <ref> Ministry of Transportation. 2010. Foundation Frost Penetration Depths for Southern Ontario. OPSD 3090.101. Nov 2010. Rev.1. https://www.library.mto.gov.on.ca/SydneyPLUS/TechPubs/Portal/tp/opsViews.aspx </ref>.<br>
 +
<br>
 
[[Weirs]] are generally less prone to clogging from ice than [[orifices]] under all flow conditions, proprietary low flow devices are also available which are designed to mitigate clogging from ice or other solid debris.
 
[[Weirs]] are generally less prone to clogging from ice than [[orifices]] under all flow conditions, proprietary low flow devices are also available which are designed to mitigate clogging from ice or other solid debris.
  

Navigation menu