Changes

Jump to navigation Jump to search
no edit summary
Line 33: Line 33:  
|'''[[Bioretention]]'''
 
|'''[[Bioretention]]'''
 
|1 (infiltrating); Not a constraint (non-infiltrating)
 
|1 (infiltrating); Not a constraint (non-infiltrating)
|5:1 to 15:1||[[Underdrain]] recommended<br>if < 15 mm/hr||1 to 2||5 to 10||0 to 2||No (infiltrating); Yes (non-infiltrating)||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||No (infiltrating); Yes (non-infiltrating)||2 yr (infiltrating); None (non-infiltrating)
+
|5:1 to 15:1||Decompaction and [[Underdrain]] recommended<br>if < 15 mm/hr||1 to 2||5 to 10||0 to 2||No (infiltrating); Yes (non-infiltrating)||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||No (infiltrating); Yes (non-infiltrating)||2 yr (infiltrating); None (non-infiltrating)
 
|-
 
|-
 
|'''[[Stormwater planters]]'''
 
|'''[[Stormwater planters]]'''
Line 41: Line 41:  
|'''[[Vegetated filter strips]]'''
 
|'''[[Vegetated filter strips]]'''
 
|Not a constraint
 
|Not a constraint
|4:1 or less||Decompact if < 15 mm/hr||0 to 1||15 to 20||1 to 5||No||None||Yes||None
+
|4:1 or less||Decompaction if < 15 mm/hr||0 to 1||15 to 20||1 to 5||No||None||Yes||None
 
|-
 
|-
 
|'''[[Permeable pavements]]'''
 
|'''[[Permeable pavements]]'''
Line 49: Line 49:  
|'''[[Enhanced swales]] (featuring check dams)'''
 
|'''[[Enhanced swales]] (featuring check dams)'''
 
|1  
 
|1  
|5:1 to 10:1||Decompact if < 15 mm/hr||1 to 3||5 to 15||0.5 to 6||No||4m- Building Foundation<br>Underground Utilities||No||2 Yr
+
|5:1 to 10:1||Decompaction if < 15 mm/hr||1 to 3||5 to 15||0.5 to 6||No||4m- Building Foundation<br>Underground Utilities||No||2 Yr
 
|-
 
|-
 
|'''[[Bioswales]] (Dry swales)'''
 
|'''[[Bioswales]] (Dry swales)'''
 
|1 (infiltrating); Not applicable (non-infiltrating)
 
|1 (infiltrating); Not applicable (non-infiltrating)
|5:1 to 15:1||Underdrain recommended <br> if < 15 mm/hr||1 to 3||5 to 10||0.5 to 6||No (infiltrating); Yes (non-infiltrating)||4m (3m if impermeable liner<br>is used) Building foundation,<br> Underground utilities,<br> Drinking Water Wellhead Protection Areas||No (infiltrating); Yes (non-infiltrating)||2 Yr (infiltrating); None (non-infiltrating)
+
|5:1 to 15:1||Decompaction and [[Underdrain]] recommended <br> if < 15 mm/hr||1 to 3||5 to 10||0.5 to 6||No (infiltrating); Yes (non-infiltrating)||4m (3m if impermeable liner<br>is used) Building foundation,<br> Underground utilities,<br> Drinking Water Wellhead Protection Areas||No (infiltrating); Yes (non-infiltrating)||2 Yr (infiltrating); None (non-infiltrating)
 
|-
 
|-
 
|'''[[Exfiltration trenches]]'''
 
|'''[[Exfiltration trenches]]'''

Navigation menu