Difference between revisions of "Liner"

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
 
(4 intermediate revisions by the same user not shown)
Line 1: Line 1:
A liner is sometime incorporated into non-infiltrating practices such as [[stormwater planters]], or has also been applied in [[permeable pavements]] installations where seperation from the native soils and groundwater was required.  
+
An impermeable liner is incorporated into non-infiltrating practices such as [[stormwater planters]], and may be applied in [[permeable pavements]] installations where separation from the native soils and groundwater is required.  
*Waterproof containment can be created using a plastic membrane/liner (HDPE or EPDM are common materials).
+
*Waterproof containment can be created using concrete or a plastic membrane/liner (HDPE or EPDM are common materials).
 
**When the membrane is being used directly in the ground, punctures from stones can be prevented by compacting a layer sand (30  - 50 mm) over the soil prior to installing the membrane.  
 
**When the membrane is being used directly in the ground, punctures from stones can be prevented by compacting a layer sand (30  - 50 mm) over the soil prior to installing the membrane.  
 
**Alternatively, a manufactured cushion fabric (geotextile) can be employed for this purpose.   
 
**Alternatively, a manufactured cushion fabric (geotextile) can be employed for this purpose.   
 
**The top surface of the membrane must also be protected from stone and gravel being used for inside the BMP. Again, sand or a cushion fabric may be used.  
 
**The top surface of the membrane must also be protected from stone and gravel being used for inside the BMP. Again, sand or a cushion fabric may be used.  
*When a pipe is used to provide drainage from the BMP cell, a 'pipe boot' should be sealed to both the pipe and the liner to prevent leaks.     
+
*When a pipe is used to provide drainage from the practice to an outlet structure or storm sewer, a 'pipe boot' or flange should be sealed to both the pipe and the liner to prevent leaks.     
 
[[Category:Materials]]
 
[[Category:Materials]]

Latest revision as of 21:17, 4 March 2022

An impermeable liner is incorporated into non-infiltrating practices such as stormwater planters, and may be applied in permeable pavements installations where separation from the native soils and groundwater is required.

  • Waterproof containment can be created using concrete or a plastic membrane/liner (HDPE or EPDM are common materials).
    • When the membrane is being used directly in the ground, punctures from stones can be prevented by compacting a layer sand (30 - 50 mm) over the soil prior to installing the membrane.
    • Alternatively, a manufactured cushion fabric (geotextile) can be employed for this purpose.
    • The top surface of the membrane must also be protected from stone and gravel being used for inside the BMP. Again, sand or a cushion fabric may be used.
  • When a pipe is used to provide drainage from the practice to an outlet structure or storm sewer, a 'pipe boot' or flange should be sealed to both the pipe and the liner to prevent leaks.