Changes

Jump to navigation Jump to search
no edit summary
Line 5: Line 5:     
The length of the level spreader should be determined by the type of filter area and the design flow:
 
The length of the level spreader should be determined by the type of filter area and the design flow:
* 1.4 m of level spreader length per every 0.01 m³/s of inflow for discharges to a [[filter strip]] or turf conservation area;
+
* 1.4 m of level spreader length per every 0.01 m³/s of inflow for discharges to a [[filter strip]] or grassed area;
 
* 4.3 m of level spreader length per every 0.01 m³/s of inflow when the spreader discharges to a forested conservation area.
 
* 4.3 m of level spreader length per every 0.01 m³/s of inflow when the spreader discharges to a forested conservation area.
 
* The minimum level spreader length is 4 m and the maximum is 40 m.
 
* The minimum level spreader length is 4 m and the maximum is 40 m.

Navigation menu